View larger
NZMN2-AF25-NA 269172 Y7-269172 EATON ELECTRIC Circuit-breaker, 3p, 25A
NZMN2-AF25-NA
269172
Y7-269172
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An NZMN2-AF25-NA 269172 Y7-269172 EATON ELECTRIC Circuit-breaker, 3p, 25A is a compact circuit-breaker engineered to safeguard electrical distribution lines from the damaging effects of thermal overloads and short circuits. Panel builders incorporate these components into machinery control panels and building distribution boards to ensure reliable circuit protection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 25 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 25 A
- Adjustment range undelayed short-circuit release (EF007131): 350 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
Specially designed for North America
CSA-C22.2 No. 5-09
IEC/EN 60947
UL/CSA
UL (File No. E31593)
CSA (File No. 22086)
IEC
CSA (Class No. 1432-01)
CSA certified
UL 489
CE marking
UL listed
UL (Category Control Number DIVQ)
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Protection unit
DIN rail (top hat rail) mounting optional
Fixed
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20
300 A (380/400 V AC-1, making and breaking capacity)
25 A (660-690 V AC-3, making and breaking capacity)
25 A (690 V AC -1, making and breaking capacity)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
6500 operations at 415 V AC-3
5000 operations at 690 V AC-3
7500 operations at 690 V AC-1
10000 operations at 400 V AC-1
System and cable protection
16 mm² - 18 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
Max. 20 mm x 5 mm direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
16 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection
4 mm² - 350 mm² (1x) at tunnel terminal