Eaton Moeller part number NS2-250-NA is an NS2-250-NA 102686 Y7-102686 EATON ELECTRIC Circuit-breaker 3p 250A, engineered to protect electrical circuits from overloads and short circuits in commercial buildings and industrial machinery. Circuit breakers of this rating ensure dependable switching and fault interruption. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 250 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 2500 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
IEC
CSA (Class No. 4652-06)
UL 489
UL/CSA
IEC 60947-2
CE marking
CSA certified
CSA (File No. 22086)
UL (Category Control Number WJAZ)
Specially designed for North America
UL listed
CSA-C22.2 No. 5-09
Product specifications
Protection unit
DIN rail (top hat rail) mounting optional
Built-in device fixed built-in technique
IP20
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and band terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
NA: min. 2 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 8 segments of 15.5 mm x 0.8 mm (2x) at terminal box
Min. 2 segments of 9 mm x 0.8 mm at box terminal
NA: max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
7500 operations at 690 V AC-1
10000 operations at 415 V AC-1
5000 operations at 690 V AC-3
6500 operations at 415 V AC-3
10000 operations at 400 V AC-1
Max. 24 mm x 8 mm direct at switch rear-side connection
NA: M8 at rear-side screw connection
Min. 16 mm x 5 mm direct at switch rear-side connection
NA: min. 16 mm x 5 mm direct at switch rear-side connection
NA: max. 20 mm x 5 mm direct at switch rear-side connection
NA: 12 - 6 AWG (1x) at box terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
4 mm² - 16 mm² (2x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
6 mm² - 16 mm² (2x) at box terminal
NA: 6 AWG (1x) at tunnel terminal
NA: 12 - 6 AWG (1x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 185 mm² (1x) at 1-hole tunnel terminal
NA: 4 - 350 AWG/kcmil (1x) at 1-hole tunnel terminal
25 mm² - 185 mm² (1x) direct at switch rear-side connection
NA: 4 - 350 AWG/kcmil (1x) at box terminal
25 mm² - 35 mm² (2x) direct at switch rear-side connection
25 mm² - 35 mm² (1x) direct at switch rear-side connection