View larger
NZMN2-S2,4-CNA 269479 Y7-269479 EATON ELECTRIC Circuit-breaker, 3p, 2.4A
NZMN2-S2,4-CNA
269479
Y7-269479
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
NZMN2-S2,4-CNA 269479 Y7-269479 EATON ELECTRIC Circuit-breaker, 3p, 2.4A functions as an industrial circuit breaker designed to protect electrical distribution grids and motor circuits from fault currents. Facilities rely on these devices to maintain electrical safety and prevent unexpected equipment damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 690 V
- Rated operation power at AC-3, 230 V (EF007025): 0.75 kW
- Rated operation power at AC-3, 400 V (EF001364): 1.5 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 195 mm
More info
▲General specifications
UL (Category Control Number DKPU2)
CSA-C22.2 No. 5-09
UL 489
Specially designed for North America
CSA (File No. 22086)
UL (File No. E31593)
CSA certified
CSA (Class No. 1432-01)
UL listed
Product specifications
Built-in device fixed built-in technique
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20
2.4 A (690 V AC-1, making and breaking capacity)
300 A (400 V AC-1, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
7500 operations at 690 V AC-1
6500 operations at 400 V AC-3
5000 operations at 690 V AC-3
6500 operations at 415 V AC-3
16 mm² - 18 mm² (2x)
Max. 20 mm x 5 mm direct at switch rear-side connection
Min. 16 mm x 5 mm direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection