View larger
NZMB2-S2,4-CNA 269473 Y7-269473 EATON ELECTRIC Circuit-breaker, 3p, 2.4A
NZMB2-S2,4-CNA
269473
Y7-269473
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Equipped with a magnetic release mechanism, the Eaton Moeller NZMB2-S2,4-CNA is a specialized circuit-breaker designed to provide short-circuit protection in industrial power systems. Engineers utilize these robust breakers to isolate faults rapidly and maintain system integrity.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 192 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated operation power at AC-3, 230 V (EF007025): 0.75 kW
- Rated operation power at AC-3, 400 V (EF001364): 1.5 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 195 mm
More info
▲General specifications
CSA (File No. 22086)
Specially designed for North America
CSA (Class No. 1432-01)
CSA-C22.2 No. 5-09
UL/CSA
CSA certified
UL listed
UL (Category Control Number DKPU2)
UL (File No. E31593)
Product specifications
Built-in device fixed built-in technique
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
2.4 A (660-690 V AC-3, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
7500 operations at 400 V AC-1
16 mm² - 18 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
Max. 20 mm x 5 mm direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
16 mm² (1x) at tunnel terminal
4 mm² - 350 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection