View larger
NZMH2-ME200-NA 118969 Y7-118969 EATON ELECTRIC Circuit-breaker, 3p, 200A, motor protection
NZMH2-ME200-NA
118969
Y7-118969
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number NZMH2-ME200-NA is a specialized motor protection circuit-breaker configured to safeguard high-power industrial motors against phase failure, thermal overload, and short-circuit conditions. These robust switching devices are installed within motor control centers to interrupt dangerous fault currents before damage can occur to the driven machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 100 A
- Adjustment range undelayed short-circuit release (EF007131): 200 A
- With thermal overload protection (EF006233): true
- Phase failure sensitive (EF007400): true
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): None A
- Rated operation power at AC-3, 230 V (EF007025): 55 kW
- Rated operation power at AC-3, 400 V (EF001364): 110 kW
- Power loss (EF005387): None W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
More info
▲General specifications
UL 489
UL/CSA
CSA (Class No. 1432-01)
IEC 60947-2
IEC
UL (File No. E31593)
UL508
IEC/EN 60947
Specially designed for North America
CSA (File No. 22086)
UL listed
UL (Category Control Number DIVQ)
CSA certified
CE marking
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Fixed
Damp heat, cyclic, to IEC 60068-2-30
300 V AC (between the auxiliary contacts)
IP20
300 A (400 V AC-1, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
200 A (660-690 V AC-3, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
6500 operations at 415 V AC-3
7500 operations at 690 V AC-1
10000 operations at 400 V AC-1
6500 operations at 400 V AC-3
Phase failure sensitive
Motor protection
16 mm² - 18 mm² (2x)
Max. 20 mm x 5 mm direct at switch rear-side connection
Min. 16 mm x 5 mm direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
16 mm² (1x) at tunnel terminal
4 mm² - 350 mm² (1x) at box terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection