View larger
NZMB2-A200-NA 269216 Y7-269216 EATON ELECTRIC Circuit-breaker, 3p, 200A
NZMB2-A200-NA
269216
Y7-269216
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Control panels and power distribution systems rely on molded case circuit breakers like the NZMB2-A200-NA 269216 Y7-269216 EATON ELECTRIC Circuit-breaker, 3p, 200A to disconnect faulty circuits and prevent electrical overloads. They provide dependable thermal and magnetic protection for commercial electrical assets.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 200 A
- Rated voltage (EF003977): 440 V
- Overload release current setting (EF002336): 160 A
- Adjustment range undelayed short-circuit release (EF007131): 1200 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
UL/CSA
CSA (Class No. 1432-01)
IEC 60947-2
Specially designed for North America
CE marking
UL listed
UL (Category Control Number DIVQ)
UL 489
IEC/EN 60947
UL (File No. E31593)
CSA certified
CSA (File No. 22086)
IEC
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 440 V
Protection unit
Fixed
DIN rail (top hat rail) mounting optional
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20
300 A (380/400 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP10 (tunnel terminal)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
6500 operations at 415 V AC-3
Current limiting circuit breaker
16 mm² - 18 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
M8 at rear-side screw connection
16 mm² (1x) at tunnel terminal
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at tunnel terminal