View larger
NZMN2-S18-CNA 103043 Y7-103043 EATON ELECTRIC Circuit-breaker, 3p, 18A
NZMN2-S18-CNA
103043
Y7-103043
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for dependable performance in panel enclosures, the NZMN2-S18-CNA 103043 Y7-103043 EATON ELECTRIC Circuit-breaker, 3p, 18A acts as a dedicated circuit protection device for low-voltage power distribution. Thermal-magnetic circuit breakers are universally applied in automation panels to guard against damaging short circuits and sustained overloads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 18 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 7 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
UL/CSA
UL (File No. E31593)
CSA certified
CSA (Class No. 1432-01)
CSA-C22.2 No. 5-09
UL (Category Control Number DKPU2)
UL 489
Specially designed for North America
UL listed
Product specifications
Motor drive optional
Fixed
DIN rail (top hat rail) mounting optional
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at box terminal
7500 operations at 690 V AC-1
6500 operations at 415 V AC-3
5000 operations at 690 V AC-3
10000 operations at 400 V AC-1
16 mm² - 18 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
Max. 20 mm x 5 mm direct at switch rear-side connection
6 mm² - 11 mm² (1x) direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection