View larger
NZMB2-S160 265737 Y7-265737 EATON ELECTRIC Circuit-breaker, 3p, 160A
NZMB2-S160
265737
Y7-265737
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Circuit-breaker, 3p, 160A NZMB2-S160 by Eaton Moeller provides high-capacity magnetic short-circuit protection within industrial switchgear assemblies.
High-current circuit breakers protect electrical infrastructure by rapidly isolating faulted zones and preventing damage to expensive distribution equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated permanent current Iu (EF001389): 160 A
- Rated operation power at AC-3, 230 V (EF007025): 45 kW
- Rated operation power at AC-3, 400 V (EF001364): 75 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
IEC
Product specifications
Built-in device fixed built-in technique
Damp heat, constant, to IEC 60068-2-78
300 V AC (between the auxiliary contacts)
IP20 (basic degree of protection, in the operating controls area)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Max. 10 segments of 24 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
10000 operations at 400 V AC-1
10 mm² - 16 mm² (2x) direct at switch rear-side connection
10 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 50 mm² (1x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at tunnel terminal
0.75 mm² - 2.5 mm² (1x)
M8 at rear-side screw connection
Min. 16 mm x 5 mm direct at switch rear-side connection
6 mm² - 16 mm² (2x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
6 mm² - 16 mm² (2x) at box terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 185 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection