View larger
NZMN2-S125-CNA 269260 Y7-269260 EATON ELECTRIC Circuit-breaker, 3p, 125A
NZMN2-S125-CNA
269260
Y7-269260
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Integrated into industrial switchgear systems, an Eaton Moeller NZMN2-S125-CNA 269260 Y7-269260 EATON ELECTRIC Circuit-breaker, 3p, 125A protects downstream electrical equipment and distribution lines from hazardous overcurrent and short-circuit conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): false
- Phase failure sensitive (EF007400): false
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 125 A
- Rated operation power at AC-3, 230 V (EF007025): 37 kW
- Rated operation power at AC-3, 400 V (EF001364): 55 kW
- Power loss (EF005387): None W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
More info
▲General specifications
UL/CSA
CSA (File No. 22086)
IEC 60947-2
CSA certified
UL 489
UL listed
IEC
UL (Category Control Number DKPU2)
CSA-C22.2 No. 5-09
CSA (Class No. 1432-01)
UL (File No. E31593)
IEC/EN 60947
CE marking
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Built-in device fixed built-in technique
Damp heat, cyclic, to IEC 60068-2-30
300 V AC (between the auxiliary contacts)
IP20 (basic degree of protection, in the operating controls area)
300 A (400 V AC-1, making and breaking capacity)
125 A (660-690 V AC-3, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
6500 operations at 415 V AC-3
7500 operations at 690 V AC-1
6500 operations at 400 V AC-3
5000 operations at 690 V AC-3
16 mm² - 18 mm² (2x)
Max. 20 mm x 5 mm direct at switch rear-side connection
M8 at rear-side screw connection
6 mm² - 12 mm² (1x) at box terminal
6 mm² - 11 mm² (1x) direct at switch rear-side connection
4 mm² - 350 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection