EATON - MOELLER CGVision Basic Package III CGVision Basic Package III 40071361024 EATON ELECTRIC CGVision Basic Package III View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CGVision Basic Package III 40071361024 EATON ELECTRIC CGVision Basic Package III

CGVision Basic Package III

40071361024

40071361024

EATON - MOELLER

1 Pcs.

CGVision Basic Package III Eaton CGL+ CGVision, CGVision Basic Package III

Automation > Visualization software
Central Battery System

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

CGVision Basic Package III 40071361024 EATON ELECTRIC CGVision Basic Package III is an electrical enclosure accessory set utilized to organize and protect internal control components within industrial distribution housings. Accessory kits of this type assist panel builders in maintaining clean cable layouts and proper mechanical ingress protection ratings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Min. required main memory for runtime system (EF003176): None MB
  • Min. required processor speed for runtime system (EF003175): None GHz

More info

▲
Pasco fuse-switch DIII
Fuse switch-disconnector 50A, D III, 1 pole, can be switched by neutral conductor, with adapter plate for fuses with 35A, 50 A
[

Delivery program

Product range
Fuse switch-disconnector
Part group reference
LPC
Number of poles
1 pole
Degree of Protection
IP20
Design
service distribution board mounting
Rated uninterrupted current [Iu]
50 A
Note on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
,

Technical data

General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Certifications
CE, RoHs; KEMA
Ambient temperatureOperation [ϑ]
-25 - +55 °C
Ambient temperatureStorage [ϑ]
-30 - +80 °C
Overvoltage category/pollution degree
III/3
Mounting position
As required
Contacts
Mechanical variablesNumber of poles
1 pole
Electrical characteristicsRated uninterrupted current [Iu]
50 A
Electrical characteristicsNote on rated uninterrupted current !u
Rated uninterrupted current Iuis specified for max. cross-section.
Heat dissipation per pole, current-dependent [Pvid]
5 W
Terminal capacities
Solid
1.5 - 16 mm2
Flexible with ferrules to DIN 46228flexible
1.5 - 10 mm2
Stripping length
8 mm
Tightening torque for terminal screw
3 Nm
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
5 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector ([email protected] [AKF058013])
Version as main switch
No
Version as safety switch
No
Max. rated operation voltage Ue AC
400 V
Rated permanent current Iu
50 A
Rated operation power at AC-23, 400 V
0 kW
Conditioned rated short-circuit current Iq
0 kA
Rated short-time withstand current lcw
0 kA
Suitable for fuses
Other
Number of poles
2
With error protection
Yes
Type of electrical connection of main circuit
Screw connection
Cable entry
Other
Equipped with connectors
Yes
Suitable for ground mounting
No
Suitable for front mounting 4-hole
No
Suitable for busbar mounting
No
Type of control element
Other
Position control element
Front side
Motor drive optional
No
Motor drive integrated
No
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20
]

Product Datasheet