EATON - MOELLER +NZM3-4-XKCU +NZM3-4-XKCU 266782 Y7-266782 EATON ELECTRIC Box terminal, 4p, bottom up to 630A, size 3. Can only be sold a.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

+NZM3-4-XKCU 266782 Y7-266782 EATON ELECTRIC Box terminal, 4p, bottom up to 630A, size 3. Can only be sold a..

+NZM3-4-XKCU

266782

Y7-266782

EATON - MOELLER

1 Pcs.

Box terminal, 4p, bottom up to 630A, size 3. Can only be sold assembled. +NZM3-4-XKCU Box terminal, 4p, bottom up to 630A, size 3 Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple. Notes: part no. suffix and part no. contain parts for a circuit-breaker side at top or bottom for 3 or 4 pole circuit-breakers. Conversion kit for circuit-breaker with screw connection. Fitted within the switch housing. O = fitted at the top. U = fitted at the bottom. U e ≧ 525 VAC. Use NZM3(-4)-XKSA cover. Use ferrules with flexible and highly flexible conductors., observe limited terminal capacity through sleeve . Can be used for: NZM3(-4), PN3(-4), N(N/O)3(-4)

Automation > Wiring set for power circuit breaker
Circuit Breakers NZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller series NZM connection type
Catalog Number
266782
Model Code
+NZM3-4-XKCU
EAN
4015082667825
Product Length/Depth
80 mm
Product Height
60 mm
Product Width
80 mm
Product Weight
0.53 kg
Compliances
IEC
RoHS conform

Product specifications

Used with
NZM3(-4), PN3(-4), N(S)3(-4)
Type
AccessoryBox terminalTerminal
Amperage Rating
≦ 630 A
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Frame
NZM3
Suitable for
Four-pole
Copper cable
Mounting position
Fitted at the bottom
Number of poles
Four-pole
Terminal capacity (copper strip)
630 A: 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm or 8 segments of 24 mm x 1 mm (2x)
Max. 500 A: 6 segments of 16 mm x 0.8 mm - 10 segments of 24 mm x 1 mm or 11 segments of 21 mm x 1 mm
Model
Other
Terminal capacity (stranded cable)
35 mm² - 240 mm² (1x)
16 mm² - 120 mm² (2x)
2 - 500 AWG/kcmil (1x)

ETIM for 266782 Low-voltage industrial controls and switchgear (EC002050)
Feature Name Feature Value
Suitable for number of poles (EF001589) 4
Model (EF000010) Other

Product Datasheet