EATON - MOELLER BB-UL-18/2P-3M/39 BB-UL-18/2P-3M/39 121985 Y7-121985 EATON ELECTRIC Phase busbar, 2-phase, 18qmm, pin, 1m View larger
Images are for illustrative purposes only. Please refer to data sheet for details

BB-UL-18/2P-3M/39 121985 Y7-121985 EATON ELECTRIC Phase busbar, 2-phase, 18qmm, pin, 1m

BB-UL-18/2P-3M/39

121985

Y7-121985

EATON - MOELLER

1 Pcs.

Phase busbar, 2-phase, 18qmm, pin, 1m BB-UL-18/2P-3M/39 Block busbar for FAZ, type conforms to UL508, EN/IEC 60947-2

Automation > Phase busbar
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Distribution configurations often rely on phase busbars like the Eaton Moeller BB-UL-18/2P-3M/39 to safely bridge multiple modular components inside control panels and electrical switchboards. These conductive comb bars streamline wiring tasks, reduce potential loose termination points, and help distribute incoming power evenly across associated circuit protection devices.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of phases (EF000351): 2
  • Number of poles (EF001391): 39
  • Suitable for number of devices (EF007241): 0
  • Module width (EF007504): 0 mm
  • Cross section (EF000649): 18 mm²
  • Length (EF001438): 690 mm
  • Can be cut to size (EF015250): Yes
  • Width in number of modular spacings (EF002950): 39
  • Rated permanent current Iu (EF001389): 80 A
  • Type of electric connection (EF003961): Pin
  • Insulated (EF000019): Yes
  • Rated surge voltage (EF002993): 10 kV
  • Conditioned rated short-circuit current Iq (EF001444): 10 kA
  • Max. rated operation voltage Ue (EF007357): 277 V
  • Rated short-time withstand current lcw (EF007050): 0 kA
  • Suitable for devices with N-conductor (EF007218): No

More info

▲
Phase busbar, 2-phase, 18qmm, pin, 1m
Block busbar for FAZ, type conforms to UL508, EN/IEC 60947-2

Delivery program

Basic function
Busbar
Basic function accessories
Busbar for miniature circuit-breaker
Application
Switchgear for industrial and advanced commercial applications
Busbar type
2 phase
Product range
BB-UL

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
80 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-5 °C
Operating ambient temperature max.
+100 °C
0

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Phase busbar (EC000215)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Phase busbar ([email protected] [ACN992011])
Number of phases
2
Number of poles
39
Suitable for number of devices
39
Pitch dimensions
0 mm
Cross section
18 mm²
Length
1000 mm
Number of modular spacings
39
Rated permanent current Iu
80 A
Type of electric connection
Pin
Insulated
Yes
Rated surge voltage
10 kV
Conditioned rated short-circuit current Iq
10 kA
Max. rated operation voltage Ue
277 V
Rated short-time withstand current lcw
0 kA
Suitable for devices with N-busbar
No
Suitable for devices with auxiliary switch
No

Characteristics

Characteristic curve

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.