EATON - MOELLER AZ-XAA(12-60VAC) AZ-XAA(12-60VAC) 212061 Y7-212061 EATON ELECTRIC Shunt release, up to 125 A, 12-60V, 1HP View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AZ-XAA(12-60VAC) 212061 Y7-212061 EATON ELECTRIC Shunt release, up to 125 A, 12-60V, 1HP

AZ-XAA(12-60VAC)

212061

Y7-212061

EATON - MOELLER

1 Pcs.

Shunt release, up to 125 A, 12-60V, 1HP AZ-XAA(12-60VAC) Eaton Distribution parts. Shunt release, up to 125A, 12-60V, 1HP Shunt release, for MCB up to 125A, voltage range 12-110V AC / 12-60V DC, rated insulation voltage 440V AC, standard front dimension 45 mm, mounting width 1 SU (17.5mm), top-hat rail mounting, terminal cross-section 1x1–25 mm² / 2x1–4 mm² solid and flexible

Automation > Auxiliary device for distribution board devices
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Distribution parts
Catalog Number
212061
Model Code
AZ-XAA(12-60VAC)
EAN
4015082120610
Product Length/Depth
80 mm
Product Height
75 mm
Product Width
39.1 mm
Product Weight
0.159 kg
Compliances
RoHS conform

Product specifications

Type
Special features
IP20 (switch)
Accessory/spare part type
Shunt release
Degree of protection
IP40
Frame
Standard front dimension: 45 mm
Frequency rating
50 Hz / 60 Hz
Used with
Accessory
Accessory for miniature circuit breaker
Admissible back-up fuse
Inherently short-circuit-proof
Mounting method
Top-hat rail IEC/EN 60715
Additional equipment required
Shunt release (for power circuit breaker)
Terminal protection
Protection against electric shock to IEC 536
Terminal type
Twin-purpose terminals
Voltage range
12 V AC - 60 V AC
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-5 °C
Assembly width
1 TE
Enclosure width
90 mm
Inrush current at AC
38 A
Inrush current at DC
34 A
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Number of poles at main contact unit - max
1
Number of switches (fault signal)
0
Pick-up time AC
2.1 ms
Rated insulation voltage (Ui)
440 VAC
Voltage type
AC/DC
Functions
Shunt release (for power circuit breaker)
Duty factor
2 ms
Device fitting
Miniature circuit breaker (MCB)
Mounting width
17.5 mm (1 space unit)
Lifespan, mechanical
4000 operations
Rated operational voltage (Ue) - max
60 V
Rated switch current
0 A
Suitable for current of main contact unit - max
0 A
Terminal capacity (cable)
1 mm² - 25 mm² (1x)
1 mm² - 4 mm² (2x)
Terminal capacity (solid wire)
1 mm² - 4 mm² (2x)
1 mm² - 25 mm² (1x)

ETIM for 212061 Modular devices for distribution board/surface mounting (EC001286)
Feature Name Feature Value
Device fitting (EF007826) Miniature circuit breaker (MCB)
Function (EF000030) Shunt release (for power circuit breaker)
Width in number of modular spacings (EF002950) 1
Number of contacts as normally open contact (EF008256) 1
Number of contacts as normally closed contact (EF008255) 1
Number of contacts as change-over contact (EF008257) 0
Number of fault-signal switches (EF007613) 0
Rated switch current (EF006706) 0 A
Rated voltage (EF000228) 60 V
Voltage type (EF000187) AC/DC
With auto test for earth leakage function (EF008727) No
Suitable for max. number of poles main contact unit (total) (EF008729) 1
Suitable for max. current main contact unit (EF008730) 0 A

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.