EATON - MOELLER VHI20-PKZ0 VHI20-PKZ0 203595 Y7-203595 EATON ELECTRIC Auxiliary contact, operates as an early-make contact, 2N/O early View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VHI20-PKZ0 203595 Y7-203595 EATON ELECTRIC Auxiliary contact, operates as an early-make contact, 2N/O early

VHI20-PKZ0

203595

Y7-203595

EATON - MOELLER

2 Pcs.

Auxiliary contact, operates as an early-make contact, 2N/O early VHI20-PKZ0 Eaton Moeller® series PKZ0 Auxiliary contact, operates as an early-make contact, 2N/O early Auxiliary contact, Contacts N/O = Normally open: 2 N/O, For use with: PKZM0, PKZM0-T, PKM0, PKZM4

Automation > Auxiliary contact block
Circuit Breakers PKZ

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series PKZ0 Accessory Auxiliary contact
Catalog Number
203595
Model Code
VHI20-PKZ0
EAN
4015082035952
Product Length/Depth
40 mm
Product Height
44 mm
Product Width
45 mm
Product Weight
0.029 kg
Certifications
CE
CSA
IEC/EN 60947-4-1
CSA Class No.: 3211-05
CSA File No.: 165628
UL 508
UL File No.: E36332
CSA-C22.2 No. 14
UL
UL Category Control No.: NLRV
Catalog Notes
For the premature voltage application of the U-release, e.g. in EMERGENCY STOP circuits according to EN 60204.

Features & Functions

Electric connection type
Screw connection

General

Lifespan, electrical
100,000 Operations
Lifespan, mechanical
100,000 Operations
Model
Top mounting
Mounting method
Front fastening
Overvoltage category
III
Pollution degree
3
Product category
Accessories
Rated impulse withstand voltage (Uimp)
4000 V AC
Used with
Motor protective circuit-breaker
PKZ0-X(R)H(-M),MSC-… and PKZM0-X…M12

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Terminal capacities

Terminal capacity (solid/flexible with ferrule)
0.75 - 1.5 mm²
Terminal capacity (solid/stranded AWG)
18 - 16

Electrical rating

Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
1 A
Rated operational current (Ie) at DC-13, 24 V
2 A
Rated operational voltage (Ue) at AC - max
440 V
Rated operational voltage (Ue) at DC - max
250 V
Safe isolation
440 V, Between auxiliary contacts and main contacts, According to EN 61140
Short-circuit protection rating without welding
10 A gG/gL, Fuse, Auxiliary contacts

Communication

Connection type
Screw connection

Contacts

Control circuit reliability
< 2 λ, < 1 failure at 100,000,000 Operations (at Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
2

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.03 W
Rated operational current for specified heat dissipation (In)
1 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 203595 Low-voltage industrial controls and switchgear (EC000041)
Feature Name Feature Value
Number of contacts as change-over contact (EF008257) 0
Number of contacts as normally open contact (EF008256) 2
Number of contacts as normally closed contact (EF008255) 0
Number of fault-signal switches (EF007613) 0
Rated operation current Ie at AC-15, 230 V (EF001385) 1 A
Type of electric connection (EF003961) Screw connection
Model (EF000010) Clip-on
Mounting method (EF000003) Front fastening
Lamp holder (EF000048) None