The Eaton Moeller DILA-XHI22 auxiliary contact module provides multiple normally open and normally closed contacts for surface mounting on control contactors. Such modules allow engineers to expand control circuit logic and feedback pathways in automated industrial switchboards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 2
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 4 A
- Type of electric connection (EF003961): Screw connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Front fastening
More info
▲General specifications
CSA-C22.2 No. 14-05
UL Category Control No.: NKCR
CSA
UL 508
VDE 0660
CSA Class No.: 3211-03
CE
IEC/EN 60947
CSA File No.: 012528
UL
UL File No.: E29184
Features & Functions
Switching elements according to EN 50005
General
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10,000,000 Operations (AC operated)
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (0.75 - 2.5) mm², Screw terminals
1 x (0.75 - 2.5) mm², Screw terminals
2, Terminal screw, Pozidriv screwdriver
Electrical rating
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
1 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
2.5 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
400 V AC, Between coil and auxiliary contacts, According to EN 61140
10 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Contacts
44 in combination with DILA(C)-22
53 in combination with DILA(C)-31
λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)