View larger
13DILE 002397 Y7-2397 EATON ELECTRIC Auxiliary contact, 1N/O+3N/C, surface mounting, screw connection
13DILE
002397
Y7-2397
EATON - MOELLER
1 Pcs.
Automation > Auxiliary contact block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller 13DILE auxiliary contact module attaches to miniature contactors to provide dependable switching for control logic and interlocking circuits. Electrical engineers rely on these top-mounting contact blocks to configure complex machine safety loops and automated sequencing. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller® series DILE Accessory Auxiliary contact module
- Catalog Number: 002397
- Model Code: 13DILE
- EAN: 4015080023975
- Product Length/Depth: 36 mm
- Product Height: 32 mm
- Product Width: 45 mm
- Product Weight: 0.04 kg
- Electric connection type: Screw connection
- Fitted with:: Interlocked opposing contacts Switching elements according to EN 50005
- Functions: For standard applications
- Number of poles: Four-pole
- Model: Top mounting
- Mounting method: Front fastening
- Mounting position: As required (except vertical with terminals A1/A2 at the bottom)
- Operating frequency: 9000 Operations/h
More info
▲General specifications
| Product Name | Eaton Moeller® series DILE Accessory Auxiliary contact module |
| Catalog Number | 002397 |
| Model Code | 13DILE |
| EAN | 4015080023975 |
| Product Length/Depth | 36 mm |
| Product Height | 32 mm |
| Product Width | 45 mm |
| Product Weight | 0.04 kg |
| Certifications | IEC/EN 60947 CSA CE UL Category Control No.: NKCR IEC/EN 60947-4-1 UL VDE 0660 UL File No.: E29184 CSA-C22.2 No. 14-05 UL 508 CSA Class No.: 3211-03 CSA File No.: 012528 |
Features & Functions
| Electric connection type | Screw connection |
| Features | Interlocked opposing contacts within an auxiliary contact module (according to IEC 60947-5-1 Annex L) |
| Fitted with: | Interlocked opposing contacts Switching elements according to EN 50005 |
| Functions | For standard applications |
| Number of poles | Four-pole |
General
| Lifespan, mechanical | 200,000 Operations (at 240 V, AC-15) 10,000,000 Operations (AC operated) 20,000,000 Operations (DC operated) 150,000 Operations (at 240 V, DC, L/R = 50 ms: 2 contacts in series 0.5 A) |
| Model | Top mounting |
| Mounting method | Front fastening |
| Mounting position | As required (except vertical with terminals A1/A2 at the bottom) |
| Operating frequency | 9000 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Shock resistance | 8 g, N/C contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
Climatic environmental conditions
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 50 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient storage temperature - min | -40 °C |
| Ambient storage temperature - max | 80 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacities
| Terminal capacity (flexible with ferrule) | 1 x (0.75 - 1.5) mm² 2 x (0.75 - 1.5) mm² |
| Terminal capacity (solid) | 1 x (0.75 - 2.5) mm² 2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid/stranded AWG) | Single 18 – 14, double 18 – 14 |
| Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver |
| Tightening torque | 1.2 Nm, Screw terminals |
Electrical rating
| Rated operational voltage (Ue) at AC - max | 600 V |
| Rated insulation voltage (Ui) | 690 V |
| Rated operational current (Ie) | 1.5 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series) 2.5 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series) 0.5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series) |
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | 4 A |
| Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V | 2 A |
| Rated operational current (Ie) at AC-15, 500 V | 1.5 A |
| Safe isolation | 300 V AC, Between coil and auxiliary contacts, According to EN 61140 300 V AC, Between auxiliary contacts, According to EN 61140 |
Short-circuit rating
| Short-circuit protection rating | 10 A fast, 500V, Maximum fuse, Short-circuit rating without welding, Contacts |
| Short-circuit protection rating without welding | 6 A gG/gL, 500 V, Max. Fuse, Contacts |
Conventional thermal current Ith
| Conventional thermal current Ith of auxiliary contacts (1-pole, open) | 10 A |
Switching capacity
| Switching capacity (auxiliary contacts, general use) | 10 A, 600 V AC, (UL/CSA) 0.5 A, 250 V DC, (UL/CSA) |
| Switching capacity (auxiliary contacts, pilot duty) | P300, DC operated (UL/CSA) A600, AC operated (UL/CSA) |
Contacts
| Code number | 53 E in combination with DILER-40(-G) 44 in combination with DILER-31(-G) 35 in combination with DILER-22 |
| Control circuit reliability | < 2 λ, < 1 failure at 100,000,000 Operations (at Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA) |
| Number of contacts (change-over contacts) | 0 |
| Number of contacts (normally closed contacts) | 3 |
| Number of contacts (normally open contacts) | 1 |
Design verification
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.24 W |
| Rated operational current for specified heat dissipation (In) | 4 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |