EATON - MOELLER DILP800-XHI-SA DILP800-XHI-SA 207471 XTCFAXSCN11 EATON ELECTRIC Auxiliary contact, 1N/O+1N/C, side exterior, screw connecti.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DILP800-XHI-SA 207471 XTCFAXSCN11 EATON ELECTRIC Auxiliary contact, 1N/O+1N/C, side exterior, screw connecti..

DILP800-XHI-SA

207471

XTCFAXSCN11

EATON - MOELLER

1 Pcs.

Auxiliary contact, 1N/O+1N/C, side exterior, screw connection Auxiliary contacts 1 NO + 1 NC External side Screw connection Auxiliary contact module, Ith= 16 A, 1 N/O, 1 NC, Side mounted, Spring-loaded terminals, DILP Auxiliary contact module, Function: for standard applications, Connection technique: Spring-loaded terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, Rated operational current AC-15 380 V 400 V 415 V: Ie= 4 A, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 1 NC, Mounting type: Side mounted, For use with: DILP250…, DILP315…, DILP500…, DILP630…, DILP800…, Type: Side-mounting auxiliary contacts

Automation > Auxiliary contact block
Contactors more than 170 A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller DILP800-XHI-SA auxiliary contact block mounts on the exterior side of heavy-duty contactors to facilitate additional signal routing and control logic. Side-mounted auxiliary units are ideal when front space on a contactor is restricted.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of contacts as change-over contact (EF008257): 0
  • Number of contacts as normally open contact (EF008256): 1
  • Number of contacts as normally closed contact (EF008255): 1
  • Number of fault-signal switches (EF007613): 0
  • Rated operation current Ie at AC-15, 230 V (EF001385): 6 A
  • Type of electric connection (EF003961): Screw connection
  • Model (EF000010): Clip-on
  • Mounting method (EF000003): Side mounting

More info

▲
Auxiliary contact module, Ith= 16 A, 1 N/O, 1 NC, Side mounted, Spring-loaded terminals, DILP
Auxiliary contact module, Function: for standard applications, Connection technique: Spring-loaded terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, Rated operational current AC-15 380 V 400 V 415 V: Ie= 4 A, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 1 NC, Mounting type: Side mounted, For use with: DILP250…, DILP315…, DILP500…, DILP630…, DILP800…, Type: Side-mounting auxiliary contacts

Delivery program

Accessories
Auxiliary contact modules
Function
for standard applications
Connection technique
Spring-loaded terminals
Rated operational current
Conventional free air thermal current, 1 poleOpenat 60 °C [Ith]
16 A
AC-15220 V 230 V 240 V [Ie]
4 A
AC-15380 V 400 V 415 V [Ie]
4 A
Contacts
N/O = Normally open
1 N/O
N/C = Normally closed
1 NC
Mounting type
Side mounted
Contact sequence
For use with
DILP250…
DILP315…
DILP500…
DILP630…
DILP800…
Type
Side-mounting auxiliary contacts

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Component lifespanat Ue= 230 V, AC-15, 3 A [Operations]
0.5 x 106
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-40 - +70 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Ambient temperatureAmbient temperature, storage
- 40 - 80 °C
Weight
0.05 kg
Contacts
N/C contact (not late-break contact) suitable as a mirror contact (to IEC/EN 60947-4-1 Annex F)
DILP250 - DILP800
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
690 V AC
Safe isolation to EN 61140between coil and auxiliary contacts
1000 V AC
Safe isolation to EN 61140between the auxiliary contacts
400 V AC
Rated operational currentConventional free air thermal current, 1 poleat 60 °C [Ith]
16 A
Rated operational currentAC-15220 V 230 V 240 V [Ie]
4 A
Rated operational currentAC-15380 V 400 V 415 V [Ie]
4 A
Rated operational currentAC-15500 V [Ie]
1 A
Rated operational currentControl circuit reliability [Failure rate]
<10-8, < one failure at 100 million operations
(at Ue= 24 V DC, Umin= 17 V, Imin= 5.4 mA) λ
Short-circuit rating without weldingShort-circuit protection maximum fuse500 V
10 A gG/gL
Current heat loss at IthAC operated
0.56 W
Current heat loss at IthDC operated
0.56 W
Current heat loss at IthCurrent heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.1 CO
Rating data for approved types
Auxiliary contactsPilot DutyAC operated
A600
Auxiliary contactsPilot DutyDC operated
N600

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
6 A
Heat dissipation per pole, current-dependent [Pvid]
0.2 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block ([email protected] [AKN342013])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
6 A
Type of electric connection
Screw connection
Model
Top mounting
Mounting method
Side mounting
Lamp holder
None

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29096
UL Category Control No.
NLDX
CSA File No.
LR72236
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.