View larger
Images are for illustrative purposes only. Please refer to data sheet for details
AUX1NO+1NC-BOX3 6101137 Y8-6101137 EATON ELECTRIC Auxiliary contact, 1 N/O + 1N/C, for DDC + QSA, Box3
AUX1NO+1NC-BOX3
6101137
Y8-6101137
EATON - MOELLER
1 Pcs.
Auxiliary contact, 1 N/O + 1N/C, for DDC + QSA, Box3
AUX1NO+1NC-BOX3
Auxiliary contact, Switching duty 6 A, 230 V AC, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 1 NC, For use with: DDC…, QSA…, Information about equipment supplied: including connection materials
Automation > Auxiliary contact block
DUMECO Switch-Disconnectors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller auxiliary contact block delivers dependable signal switching when attached to compatible circuit breakers and switch disconnectors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 6 A
- Type of electric connection (EF003961): Screw connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Front fastening
More info
▲General specifications
Product Name
Eaton Accessory Auxiliary contact
Catalog Number
6101137
Model Code
AUX1NO+1NC-BOX3
EAN
8711426214880
Product Length/Depth
50 mm
Product Height
5 mm
Product Width
50 mm
Product Weight
0.1 kg
Compliances
CE
Catalog Notes
Switching duty 6 A, 230 V AC
Features & Functions
Electric connection type
Screw connection
General
Accessories
Connection materials included with supplied equipment.
Model
Top mounting
Mounting method
Front fastening
Type
Auxiliary contact
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C
Electrical rating
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Contacts
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.11 W
Rated operational current for specified heat dissipation (In)
6 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Not applicable.
10.12 Electromagnetic compatibility
Not applicable.
10.13 Mechanical function
Not applicable.