EATON - MOELLER Eaton 9PX 1000i RT2U Netpack Eaton 9PX 1000i RT2U Netpack 9PX1000IRTN 9103-53748-KIT EATON ELECTRIC Eaton 9PX 1000i RT2U Netpack View larger
Images are for illustrative purposes only. Please refer to data sheet for details

Eaton 9PX 1000i RT2U Netpack 9PX1000IRTN 9103-53748-KIT EATON ELECTRIC Eaton 9PX 1000i RT2U Netpack

Eaton 9PX 1000i RT2U Netpack

9PX1000IRTN

9103-53748-KIT

EATON - MOELLER

1 Pcs.

Eaton 9PX 1000i RT2U Netpack Eaton 9PX UPS Netpack, 1000 VA, 1000 W, Input: C14, Outputs: (8) C13, Rack/tower, 2U, Network card included

Automation > UPS
Single-phase UPS up to 11kVA

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller Eaton 9PX 1000i RT2U Netpack 9PX1000IRTN 9103-53748-KIT EATON ELECTRIC Eaton 9PX 1000i RT2U Netpack operates as an uninterruptible power supply designed to protect sensitive networking and computing hardware from power disturbances. It provides clean, regulated backup energy to prevent operational downtime during blackouts.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Input voltage (EF003840): 100 V
  • Primary frequency (EF009272): 40 Hz
  • Number of phases primary (EF009275): 1
  • Output voltage (EF003933): 200 V
  • Secondary frequency (EF009273): 50 Hz
  • Output effective power (EF009897): 1000 W
  • Output apparent power (EF009898): 1000 VA
  • USB interface (EF002039): No
  • With communication interface RS-232 (EF007312): No
  • Number of phases secondary (EF009274): 1
  • SNMP (EF005284): Yes
  • Voltage type (EF000187): AC
  • Height (EF000040): 86.5 mm
  • Width (EF000008): 440 mm
  • Depth (EF000049): 450 mm
  • Weight (EF000167): 17.4 kg

More info

▲
Eaton 9PX 1000i RT2U Netpack
Eaton 9PX 1000i RT2U Netpack, 1000 VA, 1000 W, Input: C14, Outputs: (8) C13, Rack/tower, 2U

Technical data ETIM 7.0

Data and telecommunication (EG000037) / UPS (EC000382)
Electric engineering, automation, process control engineering / Power supply devices / No-break power supply (complete) / No-break power supply (complete, unspecified) ([email protected] [BAB258012])
Input voltage
100 - 276 V
Primary frequency
40 - 70 Hz
Number of phases primary
1
Output voltage
200 - 240 V
Secondary frequency
50 - 60 Hz
Output effective power
1000 W
Output apparent power
1000 VA
Type of interface
Other
Number of phases secondary
1
SNMP
Yes
Voltage type
AC
Height
86.5 mm
Width
440 mm
Depth
450 mm
Transition time for full load
6 min
Weight
17.4 kg
Network-management
Yes
USV- technology
Online
Construction type
482.6 mm (19 inch) device
Max. voltage distortion output (linear load)
3 %
Output power factor
1
Overall efficiency
91.5 %
Efficiency in eco-mode
97.5 %
Potential free switch contact
Yes
Auto shut down function
Yes
Input connection
C14
Number of output connections C13
8
Number of output connections C19
0
Number of output connections with protective contact (SCHUKO)
0
Number of output connections fixed connection
0