EATON - MOELLER 7.2KV 90AMP 3" AIR FUSE DCR 3565 7.2KV 90AMP 3" AIR FUSE DCR 3565 7.2BFGHO90 EATON ELECTRIC Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 4.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7.2KV 90AMP 3" AIR FUSE DCR 3565 7.2BFGHO90 EATON ELECTRIC Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 4..

7.2KV 90AMP 3" AIR FUSE DCR 3565

72BFGHO90

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 441 x 76 mm, back-up, BS, with striker fuse cartridge Air, MT, 90 A, AC 7.2 kV, 441 x 76 mm, back-up, BS, with striker Fuse, Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 441 x 76 mm, back-up, BS, with striker, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller 7.2KV 90AMP 3" AIR FUSE DCR 3565 is a medium voltage air fuse-link designed to protect primary transformer circuits from dangerous fault currents. These components are standard within electrical distribution switchgear to maintain overall grid integrity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current (EF000227): 90 A
  • Rated voltage (EF000228): 7.2 kV
  • Voltage type (EF000187): AC
  • Rated frequency (EF001663): 50 Hz
  • Breaking capacity (EF005617): 40 kA
  • Application (EF000041): Primary side transformer protection
  • Length (EF001438): 446 mm
  • Diameter (EF000551): 76 mm
  • Performance category according to IEC 60282-1 (EF012539): Back-up
  • With striker (EF008175): Yes
  • Standard (EF009322): British Standard
  • Installation technique (EF001474): Air

More info

▲
Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 441 x 76 mm, back-up, BS, with striker
Fuse, Air fuse-link, medium voltage, 90 A, AC 7.2 kV, 441 x 76 mm, back-up, BS, with striker, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 40 kA

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
90 A
Rated voltage
AC 7.2 kV
Size
441 x 76 mm
Utilization category
back-up
Status indicator
with striker
Breaking Capacity
40 kA
usable for size/applications
protection of primary side transformers
used in fuse switch combination units, fuse bases and fuse switches
Standard/Approval
BS
Shape
cylindrical
offset bolted tags
Standards/Regulations
BS2962-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
90 A
Rated voltage
7.2 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
40 kA
Utilization category
Other
Application
Primary side transformer protection
Length
441 mm
Diameter
76 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.