EATON - MOELLER 7.2KV 31.5AMP AIR FUSE 1120 7.2KV 31.5AMP AIR FUSE 1120 7.2BDGHC31.5 7-2BDGHC31-5 EATON ELECTRIC Air fuse-link, medium voltage, 125 A, A.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7.2KV 31.5AMP AIR FUSE 1120 7.2BDGHC31.5 7-2BDGHC31-5 EATON ELECTRIC Air fuse-link, medium voltage, 125 A, A..

7.2KV 31.5AMP AIR FUSE 1120

72BDGHC315

7-2BDGHC31-5

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 125 A, AC 12 kV, 76 x 359 mm, back-up, BS, with striker, style 6B tags fuse cartridge Air, MT, 31.5 A, AC 7.2 kV, BS TA3, 461 x 50.8 mm, back-up, BS, with striker 7.2BDGHC31.5 - Air fuse-link, medium voltage, 31.5 A, AC 7.2 kV, BS TA3, 461 x 50.8 mm, back-up, BS, with striker Fuse, Air fuse-link, medium voltage, 31.5 A, AC 7.2 kV, BS TA3, 461 x 50.8 mm, back-up, BS, with striker, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Air fuse-link, medium voltage, 31.5 A, AC 7.2 kV, BS TA3, 461 x 50.8 mm, back-up, BS, with striker
Fuse, Air fuse-link, medium voltage, 31.5 A, AC 7.2 kV, BS TA3, 461 x 50.8 mm, back-up, BS, with striker, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 40 kA

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
31.5 A
Rated voltage
AC 7.2 kV
Construction size
BS TA3
Size
461 x 50.8 mm
Utilization category
back-up
Status indicator
with striker
Breaking Capacity
40 kA
usable for size/applications
protection of primary side transformers
used in fuse switch combination units, fuse bases and fuse switches
Standard/Approval
BS
Shape
cylindrical
offset bolted tags
Standards/Regulations
BS2962-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
31.5 A
Rated voltage
7.2 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
40 kA
Utilization category
Other
Application
Primary side transformer protection
Length
461 mm
Diameter
51 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

ETIM for 7.2BDGHC31.5 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 31.5 A
Rated voltage (EF000228) 7.2 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 461 mm
Diameter (EF000551) 51 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air