View larger
Images are for illustrative purposes only. Please refer to data sheet for details
630AMP 660V AC / 400V DC 630R12-660 EATON ELECTRIC 630AMP 660V AC / 400V DC
630AMP 660V AC / 400V DC
630R12660
EATON - MOELLER
1 Pcs.
630AMP 660V AC / 400V DC
630AMP 660V AC/400V DC FUSE - Fuse-link, low voltage, 630 A, AC 660 V, DC 400 V, BS88, 74 x 262 mm, gL/gG, IEC
Fuse, Fuse-link, low voltage, 630 A, AC 660 V, DC 400 V, BS88, 74 x 262 mm, gL/gG, IEC, cylindrical with centre-bolted tags, traction, BS88-1, BS88-2, IEC 60269-1, IEC 60269-2, Breaking Capacity 80 kA, Optional accessories, Supplied with
Automation > HRC fuse
Bussmann fuses
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller 630AMP 660V AC / 400V DC is a heavy-duty industrial fuse-link implemented in power distribution switchboards to protect against high fault currents and cable overloads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated current (EF000227): 630 A
- Utilization category according to IEC 60269 (EF002572): gG (cable protection/equipment protection)
- Breaking capacity (EF005617): 80 kA
More info
▲Fuse-link, low voltage, 630 A, AC 660 V, DC 400 V, BS88, 74 x 262 mm, gL/gG, IEC
Fuse, Fuse-link, low voltage, 630 A, AC 660 V, DC 400 V, BS88, 74 x 262 mm, gL/gG, IEC, cylindrical with centre-bolted tags, traction, BS88-1, BS88-2, IEC 60269-1, IEC 60269-2, Breaking Capacity 80 kA, Optional accessories, Supplied with
Delivery program
Product range
Fuse
Basic function
Fuse-link
Field of application
low voltage
Rated current [I]
630 A
Rated voltage
AC 660 V
DC 400 V
DC 400 V
Construction size
BS88
Size
74 x 262 mm
Utilization category
gL/gG
Breaking Capacity
80 kA
usable for size/applications
traction
Standard/Approval
IEC
Shape
cylindrical with centre-bolted tags
Standards/Regulations
BS88-1
BS88-2
IEC 60269-1
IEC 60269-2
BS88-2
IEC 60269-1
IEC 60269-2
Technical data ETIM 7.0
Circuit breakers and fuses (EG000020) / Low Voltage HRC fuse (EC000055)
Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse inserts / Low-Voltage HRC fuse ([email protected] [AFZ800015])
Construction size
Other
Rated current
630 A
Rated voltage
660 V
Voltage type
AC/DC
Rated switching capacity
80 kA
Utilization category
gL/gG (cable protection/equipment protection)
Type of fuse status indicator
None
Insulated metal gripping lugs (IMGL)
No