EATON - MOELLER 46KV 60A EXPULSION LINK 46KV 60A EXPULSION LINK 46TB60 EATON ELECTRIC NH fuse-switch 3p box terminal 1,5 95 mm² busbar 60 mm NH000 &.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

46KV 60A EXPULSION LINK 46TB60 EATON ELECTRIC NH fuse-switch 3p box terminal 1,5 95 mm² busbar 60 mm NH000 &..

46KV 60A EXPULSION LINK

46TB60

46TB60

EATON - MOELLER

10 Pcs.

NH fuse-switch 3p box terminal 1,5 - 95 mm²; busbar 60 mm; NH000 & NH00 46KV 60A EXPULSION LINK Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, T slow, style B termination Fuse, Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, T slow, fixed NEMA button head link, protection of transformer primary side, feeder, capacitor bank, ANSI C37-42, Breaking Capacity 8 kA

Automation > Expulsion fuse-link, medium voltage
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller expulsion fuse-link, medium voltage is applied in electrical distribution infrastructure to clear line faults and protect connected assets. These fuses integrate with overhead cutouts to provide reliable, visible fault clearance in outdoor utility environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current (EF000227): 60 A
  • Rated voltage (EF000228): 46 kV
  • Voltage type (EF000187): AC
  • Rated frequency (EF001663): 50 Hz
  • Release characteristic (EF000889): T
  • Type of termination (EF012540): Fixed buttonhead
  • Standard (EF009322): ANSI

More info

▲

General specifications

Product Name
Eaton Bussmann series medium voltage expulsion fuse
Catalog Number
46TB60
EAN
5027590481656
Product Length/Depth
225 mm
Product Height
76 mm
Product Width
106 mm
Product Weight
0.133 g
Certifications
ANSI/IEEE Std C37.42

Electrical data

Amperage Rating
60 A
Voltage rating
46 kV
Voltage type
AC
Current characteristic type
Type T - Complies with ANSI C 37-42 requirements for slow acting T characteristics
Rated frequency - min
50 Hz

Product specification

Construction size
787 mm
Standard
ANSI
Type of termination
Fixed buttonhead
Color
Green

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.