EATON - MOELLER 46KV 60 AMP LINK 46KD60 46KV 60 AMP LINK 46KD60 46KD60 1624009 EATON ELECTRIC NH fuse-switch 3p box terminal 1,5 95 mm² busbar 60 mm.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

46KV 60 AMP LINK 46KD60 46KD60 1624009 EATON ELECTRIC NH fuse-switch 3p box terminal 1,5 95 mm² busbar 60 mm..

46KV 60 AMP LINK 46KD60

46KD60

1624009

EATON - MOELLER

10 Pcs.

NH fuse-switch 3p box terminal 1,5 - 95 mm²; busbar 60 mm; NH000 & NH00 Expulsion fuse cartridge, MT, 60 A, AC 46 kV, 787 mm, ANSI, K fast 46KD60 - Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, K fast, style D termination Fuse, Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, K fast, Double tailed link without NEMA button head, protection of transformer primary side, feeder, capacitor bank, ANSI C37-42, Breaking Capacity 8 kA

Automation > Expulsion fuse-link, medium voltage
Bussmann fuses

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A 46KV 60 AMP LINK 46KD60 from Eaton Moeller provides reliable overcurrent protection within industrial power distribution and medium-voltage switchgear assemblies. Such expulsion links clear hazardous fault currents quickly to prevent widespread system outages. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current (EF000227): 60 A
  • Rated voltage (EF000228): 46 kV
  • Voltage type (EF000187): AC
  • Rated frequency (EF001663): 50 Hz
  • Release characteristic (EF000889): K
  • Type of termination (EF012540): Double tail
  • Standard (EF009322): ANSI

More info

▲
Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, K fast, style D termination
Fuse, Expulsion fuse-link, medium voltage, 60 A, AC 46 kV, 787 mm, ANSI, K fast, Double tailed link without NEMA button head, protection of transformer primary side, feeder, capacitor bank, ANSI C37-42, Breaking Capacity 8 kA

Delivery program

Product range
Fuse
Basic function
Expulsion fuse-link
Field of application
medium voltage
Rated current [I]
60 A
Rated voltage
AC 46 kV
Size
787 mm
Description
Double tailed link without NEMA button head
Breaking Capacity
8 kA
usable for size/applications
protection of transformer primary side, feeder, capacitor bank
Release characteristic [class]
K fast
Standard/Approval
ANSI
Standards/Regulations
ANSI C37-42

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.