EATON - MOELLER 46KV 15AMP LINK 46TD15 46KV 15AMP LINK 46TD15 46TD15 EATON ELECTRIC Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, AN.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

46KV 15AMP LINK 46TD15 46TD15 EATON ELECTRIC Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, AN..

46KV 15AMP LINK 46TD15

46TD15

EATON - MOELLER

25 Pcs.

Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, ANSI, T slow, style D termination Ejection Fuse Cartridge, MT, 15 A, AC 46 kV, 787 mm, ANSI, T slow Fuse, Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, ANSI, T slow, Double tailed link without NEMA button head, protection of transformer primary side, feeder, capacitor bank, ANSI C37-42, Breaking Capacity 8 kA

Automation > Expulsion fuse-link, medium voltage
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Utilized in electrical utility systems, the Eaton Moeller 46KV 15AMP LINK 46TD15 provides dependable overcurrent protection and fault isolation for medium-voltage lines. Double tail configurations ensure secure mechanical connection within compatible fuse cutouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current (EF000227): 15 A
  • Rated voltage (EF000228): 46 kV
  • Voltage type (EF000187): AC
  • Rated frequency (EF001663): 50 Hz
  • Release characteristic (EF000889): T
  • Type of termination (EF012540): Double tail
  • Standard (EF009322): ANSI

More info

▲
Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, ANSI, T slow, style D termination
Fuse, Expulsion fuse-link, medium voltage, 15 A, AC 46 kV, 787 mm, ANSI, T slow, Double tailed link without NEMA button head, protection of transformer primary side, feeder, capacitor bank, ANSI C37-42, Breaking Capacity 8 kA

Delivery program

Product range
Fuse
Basic function
Expulsion fuse-link
Field of application
medium voltage
Rated current [I]
15 A
Rated voltage
AC 46 kV
Size
787 mm
Description
Double tailed link without NEMA button head
Breaking Capacity
8 kA
usable for size/applications
protection of transformer primary side, feeder, capacitor bank
Release characteristic [class]
T slow
Standard/Approval
ANSI
Standards/Regulations
ANSI C37-42

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.