EATON - MOELLER 38KV 0.5A CAV FUSE 38KV 0.5A CAV FUSE 38CAVH0.5E 38CAVH0-5E EATON ELECTRIC cartridge fuse VT, MT, 0.5 A, AC 38 kV, 440 x 41.3 m.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

38KV 0.5A CAV FUSE 38CAVH0.5E 38CAVH0-5E EATON ELECTRIC cartridge fuse VT, MT, 0.5 A, AC 38 kV, 440 x 41.3 m..

38KV 0.5A CAV FUSE

38CAVH05E

38CAVH0-5E

EATON - MOELLER

3 Pcs.

cartridge fuse VT, MT, 0.5 A, AC 38 kV, 440 x 41.3 mm, back-up, IEC, US, 0.5 AND 38KV 0.5A CAV FUSE VT fuse-link, medium voltage, 0.5 A, AC 38 kV, 40 kA, 440 x 41.3 mm, back-up, IEC, US, type E, 0.5E Fuse, VT fuse-link, medium voltage, 0.5 A, AC 38 kV, 440 x 41.3 mm, back-up, IEC, US, 0.5E, cylindrical, type E, voltage and auxiliary transformers, IEC 60282-1, ANSI C37-41, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

VT fuse-link, medium voltage, 0.5 A, AC 38 kV, 40 kA, 440 x 41.3 mm, back-up, IEC, US, type E, 0.5E
Fuse, VT fuse-link, medium voltage, 0.5 A, AC 38 kV, 440 x 41.3 mm, back-up, IEC, US, 0.5E, cylindrical, type E, voltage and auxiliary transformers, IEC 60282-1, ANSI C37-41, Breaking Capacity 40 kA

Delivery program

Product range
Fuse
Basic function
VT fuse-link
Field of application
medium voltage
Rated current [I]
0.5 A
Rated voltage
AC 38 kV
Size
440 x 41.3 mm
Utilization category
back-up
Description
type E
Breaking Capacity
40 kA
usable for size/applications
voltage and auxiliary transformers
Release characteristic [class]
0.5E
Standard/Approval
IEC
US
Shape
cylindrical
Standards/Regulations
IEC 60282-1
ANSI C37-41

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
0.5 A
Rated voltage
38 kV
Voltage type
AC
Rated frequency
60 - 60 Hz
Breaking capacity
40 kA
Utilization category
Other
Application
Auxiliary transformer protection
Length
440 mm
Diameter
41.3 mm
Performance category according to IEC 60282-1
Back-up
With striker
No
Standard
IEC
Release characteristic
E
Installation technique
Air

ETIM for 38CAVH0.5E Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 0.5 A
Rated voltage (EF000228) 38 kV
Voltage type (EF000187) AC
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Auxiliary transformer protection
Length (EF001438) 439 mm
Diameter (EF000551) 41 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) IEC
Release characteristic (EF000889) E
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.