This Eaton Moeller PV-3-5A10F85L is a specialized photovoltaic protection fuse built to safeguard DC solar arrays and combiner boxes from high-voltage fault currents. Solar fuses provide reliable overcurrent isolation in renewable energy circuits where specialized DC breaking capabilities are required. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated current: I
- Model (EF000010): Fiberglass fuse
- Voltage type (EF000187): DC
- Rated current (EF000227): 3.5 A
- Utilization category according to IEC 60269 (EF002572): gPV (photovoltaic protection)
- Power loss at rated current (EF012389): 2.6 W
More info
▲Product range | Fuse | ||
Basic function | Fuse-link | ||
Field of application | high speed | ||
Rated current | I | A | 3.5 |
Rated voltage | DC 1000 V | ||
Construction size | IEC 60269-6 type A | ||
Size | 10 x 38 mm | ||
Utilization category | gPV | ||
Breaking Capacity | kA | 50 | |
usable for size/applications | protection of solar PV strings | ||
Standard/Approval | gPV UL PV | ||
Shape | cylindrical | ||
Standards/Regulations | IEC 60269-6 UL 2579 | ||
Optional accessories | fuse-holder CHPV1U |
| Circuit breakers and fuses (EG000020) / Cylindrical fuse (EC002704) | |||
| Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse inserts / Cylindrical fuse (safety fuse) ([email protected] [AFZ797013]) | |||
Size | 10x38 mm | ||
Rated voltage | V | 1000 - 1000 | |
Rated voltage | Other | ||
Voltage type | DC | ||
Voltage type | DC | ||
Utilization category | Other | ||
Rated operating frequency | Hz | 0 - 0 | |
Nominal current | A | 3,5 | |
With striker | No | ||
Release characteristic | Other | ||
Breaking capacity | kA | 50 | |