EATON - MOELLER 302369 302369 EATON ELECTRIC FRBMM-B16/2/003-A-120. RCD/MCB comb. switch, 16A, 30mA, miniature circuit-br. type B t.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

302369 EATON ELECTRIC FRBMM-B16/2/003-A-120. RCD/MCB comb. switch, 16A, 30mA, miniature circuit-br. type B t..

302369

302369

Y7-302369

EATON - MOELLER

1 Pcs.

FRBMM-B16/2/003-A-120. RCD/MCB comb. switch, 16A, 30mA, miniature circuit-br. type B trip characteristic, 2 Pole, residual current circuit-br. trip characteristic: A, 120V High-quality residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Automation > Earth leakage circuit breaker
Modular Switchgear – Tertiary and Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller FRBMM-B16/2/003-A-120 is an RCD/MCB combination switch engineered to deliver integrated short-circuit protection and differential current monitoring within specialized electrical distribution setups. These devices prevent equipment damage and safeguard personnel by interrupting power during overloads and leakage events.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (total) (EF008618): 2
  • Number of protected poles (EF005548): 2
  • Rated voltage (EF000228): 120 V
  • Rated insulation voltage Ui (EF001366): 500 V
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Rated current (EF000227): 16 A
  • Rated fault current (EF002358): 0.03 A
  • Leakage current type (EF002560): A
  • Current limiting class (EF002568): 3
  • Disconnection characteristic (EF012587): Undelayed
  • Surge current capacity (EF002564): 0.25 kA
  • Voltage type (EF000187): AC
  • Frequency (EF005455): 50/60 Hz
  • Release characteristic (EF000889): B
  • Concurrently switching neutral conductor (EF005997): No
  • With interlocking device (EF007385): No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.