FRBMM-B16/2/003-A-120. RCD/MCB comb. switch, 16A, 30mA, miniature circuit-br. type B trip characteristic, 2 Pole, residual current circuit-br. trip characteristic: A, 120V High-quality residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Automation > Earth leakage circuit breaker
Modular Switchgear – Tertiary and Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info


ETIM for 302369 Circuit breakers and fuses (EC000905)
Feature Name Feature Value
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 2
Rated voltage (EF000228) 120 V
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated current (EF000227) 16 A
Rated fault current (EF002358) 0.03 A
Leakage current type (EF002560) A
Current limiting class (EF002568) 3
Rated short-circuit breaking capacity according to EN 61009 (EF012628) 10 kA
Rated short-circuit breaking capacity according to IEC 60947-2 (EF006065) 0 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 (EF011981) 10 kA
Disconnection characteristic (EF012587) Undelayed
Surge current capacity (EF002564) 0.25 kA
Voltage type (EF000187) AC
Frequency (EF005455) 50/60 Hz
Release characteristic (EF000889) B
Concurrently switching neutral conductor (EF005997) No
With interlocking device (EF007385) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Ambient temperature during operating (EF007515) -25 °C
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 75.5 mm
Anti-nuisance tripping version (EF009497) No
Degree of protection (IP) (EF005474) IP20
Connectable conductor cross section solid-core (EF007337) 1 mm²
Connectable conductor cross section multi-wired (EF007343) 1 mm²