EATON - MOELLER 24KV 50A 2.5" OIL FUSE 24KV 50A 2.5" OIL FUSE 24OEGN4350 EATON ELECTRIC Oil fuse-link, medium voltage, 50 A, AC 24 kV, 64 x 359 mm,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

24KV 50A 2.5" OIL FUSE 24OEGN4350 EATON ELECTRIC Oil fuse-link, medium voltage, 50 A, AC 24 kV, 64 x 359 mm,..

24KV 50A 2.5" OIL FUSE

24OEGN4350

EATON - MOELLER

3 Pcs.

Oil fuse-link, medium voltage, 50 A, AC 24 kV, 64 x 359 mm, back-up, BS Oil fuse cartridge, MT, 50 A, AC 22 kV, 64 x 359 mm, back-up, BS Fuse, Oil fuse-link, medium voltage, 50 A, AC 22 kV, 64 x 359 mm, back-up, BS, cylindrical with special tag, oil-tight, protection of primary side transformers, BS2692-1

Automation > Medium-/high voltage fuse
Bussmann fuses

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Oil fuse-link, medium voltage, 50 A, AC 24 kV, 64 x 359 mm, back-up, BS
Fuse, Oil fuse-link, medium voltage, 50 A, AC 24 kV, 64 x 359 mm, back-up, BS, cylindrical with special tag, oil-tight, protection of primary side transformers, BS2692-1

Delivery program

Product range
Fuse
Basic function
Oil fuse-link
Field of application
medium voltage
Rated current [I]
50 A
Rated voltage
AC 22 kV
Size
64 x 359 mm
Utilization category
back-up
Description
oil-tight
usable for size/applications
protection of primary side transformers
Standard/Approval
BS
Shape
cylindrical with special tag
Standards/Regulations
BS2692-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
50 A
Rated voltage
24 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
25 kA
Utilization category
Other
Application
Primary side transformer protection
Length
359 mm
Diameter
63.5 mm
Performance category according to IEC 60282-1
Back-up
With striker
No
Standard
British Standard
Release characteristic
Other
Installation technique
Oil

ETIM for 24OEGN4350 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 50 A
Rated voltage (EF000228) 24 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 25 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 359 mm
Diameter (EF000551) 63.5 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Oil

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.