EATON - MOELLER 24KV 3.15AMP 3" 'A' AIR FUSE N/S 24KV 3.15AMP 3" 'A' AIR FUSE N/S 24AFINA3.15 24AFINA3-15 EATON ELECTRIC Air fuse-link, medium voltage, 3.15 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

24KV 3.15AMP 3" 'A' AIR FUSE N/S 24AFINA3.15 24AFINA3-15 EATON ELECTRIC Air fuse-link, medium voltage, 3.15 ..

24KV 3.15AMP 3" 'A' AIR FUSE N/S

24AFINA315

24AFINA3-15

EATON - MOELLER

1 Pcs.

24KV 3.15AMP 3" 'A' AIR FUSE N/S 24KV 3.15AMP 3" 'A' AIR FUSE N/S - Air fuse-link, medium voltage, 3.15 A, AC 24 kV, 16 kA, BS AF4, 565 x 76.2 mm, back-up, BS, no striker Fuse, Air fuse-link, medium voltage, 3.15 A, AC 24 kV, BS AF4, 565 x 76.2 mm, back-up, BS, cylindrical, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 16 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage BS air fuse
Catalog Number
24AFINA3.15
EAN
5027590037785
Product Length/Depth
567 mm
Product Height
76.2 mm
Product Width
76.2 mm
Product Weight
0.001 g
Compliances
BS 2692-1
Certifications
KEMA Certified

Electrical data

Amperage Rating
3.15 A
Voltage rating
24 kV
Voltage type
AC
Breaking capacity
16 kA
Performance Cat According To IEC 60282-1
Back-up
Rated frequency - min
50 Hz
Class
Class back-up

Product specification

Fuse indicator
Non Indicating
Construction size
76.2 x 565 mm
Standard
British Standard
Standard
British Standard
Mounting method
Clip-in

ETIM for 24AFINA3.15 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 3.15 A
Rated voltage (EF000228) 24 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 16 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 567 mm
Diameter (EF000551) 76 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.