EATON - MOELLER 24KV 20AMP 3" 'A' AIR FUSE 24KV 20AMP 3" 'A' AIR FUSE 24AFIHA20 0002465695 EATON ELECTRIC cartridge fuse Air, MT, 20 A, AC 24 kV, BS BF.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

24KV 20AMP 3" 'A' AIR FUSE 24AFIHA20 0002465695 EATON ELECTRIC cartridge fuse Air, MT, 20 A, AC 24 kV, BS BF..

24KV 20AMP 3" 'A' AIR FUSE

24AFIHA20

0002465695

EATON - MOELLER

1 Pcs.

cartridge fuse Air, MT, 20 A, AC 24 kV, BS BF4, 565 x 76.2 mm, back-up, BS, with striker 24KV 20AMP 3" 'A' AIR FUSE 24KV 20AMP 3" 'A' AIR FUSE - Air fuse-link, medium voltage, 20 A, AC 24 kV, 16 kA, BS AF4, 565 x 76.2 mm, back-up, BS, with striker

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Air fuse-link, medium voltage, 20 A, AC 24 kV, 16 kA, BS AF4, 565 x 76.2 mm, back-up, BS, with striker
Fuse, Air fuse-link, medium voltage, 20 A, AC 24 kV, BS AF4, 565 x 76.2 mm, back-up, BS, with striker, cylindrical, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 16 kA

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
20 A
Rated voltage
AC 24 kV
Construction size
BS AF4
Size
565 x 76.2 mm
Utilization category
back-up
Status indicator
with striker
Breaking Capacity
16 kA
usable for size/applications
protection of primary side transformers
used in fuse switch combination units, fuse bases and fuse switches
Standard/Approval
BS
Shape
cylindrical
Standards/Regulations
BS2962-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
20 A
Rated voltage
24 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
16 kA
Utilization category
Other
Application
Primary side transformer protection
Length
565 mm
Diameter
76 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

Product Datasheet