EATON - MOELLER 16A 500VDC IND DCR 3558 16A 500VDC IND DCR 3558 16KS09 EATON ELECTRIC Air fuse-link, medium voltage, 25 A, AC 36 kV, 50.8 x 565mm, b.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

16A 500VDC IND DCR 3558 16KS09 EATON ELECTRIC Air fuse-link, medium voltage, 25 A, AC 36 kV, 50.8 x 565mm, b..

16A 500VDC IND DCR 3558

16KS09

EATON - MOELLER

20 Pcs.

Air fuse-link, medium voltage, 25 A, AC 36 kV, 50.8 x 565mm, back-up, BS, with striker, style 36 tags fuse cartridge, BT, 16 A, DC 500 V, BS88, 22 x 127 mm, gL/gG, BS Fuse, Fuse-link, low voltage, 16 A, DC 500 V, BS88, 22 x 127 mm, gL/gG, BS, centre-bolted tags, general industrial applications, BS88-2, IEC 60269-2, Breaking Capacity 40 kA

Automation > HRC fuse
Bussmann Series Low Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Air fuse-link, medium voltage, 25 A, AC 36 kV, 50.8 x 565mm, back-up, BS, with striker, style 36 tags
Fuse, Air fuse-link, medium voltage, 25 A, AC 36 kV, 50.8 x 565mm, back-up, BS, with striker, cylindrical, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS 2692-1, Breaking Capacity 16 kA
[

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
25 A
Rated voltage
AC 36 kV
Size
50.8 x 565mm
Utilization category
back-up
Status indicator
with striker
Breaking Capacity
16 kA
usable for size/applications
protection of primary side transformers
used in fuse switch combination units, fuse bases and fuse switches
Standard/Approval
BS
Shape
cylindrical
Standards/Regulations
BS 2692-1
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
25 A
Rated voltage
36 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
16 kA
Utilization category
Other
Application
Primary side transformer protection
Length
565 mm
Diameter
51 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air
]

ETIM for 16KS09 Circuit breakers and fuses (EC004556)
Feature Name Feature Value
Rated current (EF000227) 16 A
Utilization category according to IEC 60269 (EF002572) gG (cable protection/equipment protection)
Breaking capacity (EF005617) 40 kA
Type of fuse status indicator (EF004473) None

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.