View larger
167811 Y7-167811 EATON ELECTRIC DOL starter, 1-4A, protection electronic, standard
167811
167811
Y7-167811
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DOL starter bearing part number 167811 delivers direct-on-line switching and electronic motor protection for industrial machine drives. Standardized motor starter combinations integrate disconnects, contactors, and overload relays to safeguard equipment from overcurrent events.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.75 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 1.47 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 16.7 A
- Rated operation current at AC-3, 400 V (EF009602): 4 A
- Overload release current setting (EF002336): 1 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲General specifications
UL60947-4-1A
CSA Class No.: 3211-08
CSA
VDE 0660
IEC/EN 60947-4-1
UL File No.: E123500
CE
CSA File No.: 012528
UL Category Control No.: NKJH
UL
Features & Functions
General
Note: Going below the minimum current flow time can cause overheating of the load (motor).
1000 (Class 20) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
500 (Class 5) AC-4 cycle operation, Main conducting paths
700 (Class 10) AC-4 cycle operation, Main conducting paths
NEMA Other
Climatic environmental conditions
Electrical rating
1 A, 250 V DC, (UL/CSA)
A600, AC operated (UL/CSA)
Short-circuit rating
18 kA, 480 Y/277 V, SCCR (UL/CSA)