View larger
167808 Y7-167808 EATON ELECTRIC DOL starter, 3-12A, protection electronic, standard
167808
167808
Y7-167808
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A direct-on-line starter serves as an electromechanical device designed to switch industrial electric motors directly across the supply voltage, providing immediate full torque delivery upon startup. This Eaton Moeller 167808 unit integrates electronic overload monitoring to protect machinery against excessive thermal stress during continuous duty cycles.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 220 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 3 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 5.52 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 16.7 A
- Rated operation current at AC-3, 400 V (EF009602): 12 A
- Overload release current setting (EF002336): 3 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲General specifications
UL Category Control No.: NKJH
VDE 0660
UL File No.: E123500
IEC/EN 60947-4-1
UL60947-4-1A
CSA
CE
CSA Class No.: 3211-08
CSA File No.: 012528
UL
Features & Functions
General
Note: Going below the minimum current flow time can cause overheating of the load (motor).
500 (Class 5) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths
700 (Class 10) AC-4 cycle operation, Main conducting paths
NEMA Other
Climatic environmental conditions
Electrical rating
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Short-circuit rating
5 kA, SCCR (UL/CSA)
60 A, max. CB, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
25 A, max. CB, SCCR (UL/CSA)
35 A, Class J/CC, max. Fuse, SCCR (UL/CSA)
35 A, Class J/CC, max. Fuse, SCCR (UL/CSA)
18 kA, 240 V, SCCR (UL/CSA)