12 Pcs.

cartridge fuse VT, MT, 3.15 A, AC 15.5 kV, 195 mm x 25.4 mm, back-up, BS, IEC VT fuse cartridge, MT, 3.15 A, AC 15.5 kV, 195 x 25.4 mm, back-up, BS, IEC 15.5ABCNA3.15 - VT fuse-link, medium voltage, 3.15 A, AC 15.5 kV, 195 x 25.4 mm, back-up, BS, IEC Fuse, VT fuse-link, medium voltage, 3.15 A, AC 15.5 kV, 195 x 25.4 mm, back-up, BS, IEC, cylindrical, voltage and auxiliary transformers, BS2692-1, IEC 60282-1, Breaking Capacity 45 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

VT fuse-link, medium voltage, 3.15 A, AC 15.5 kV, 195 x 25.4 mm, back-up, BS, IEC
Fuse, VT fuse-link, medium voltage, 3.15 A, AC 15.5 kV, 195 x 25.4 mm, back-up, BS, IEC, cylindrical, voltage and auxiliary transformers, BS2692-1, IEC 60282-1, Breaking Capacity 45 kA

Delivery program

Product range
Fuse
Basic function
VT fuse-link
Field of application
medium voltage
Rated current [I]
3.15 A
Rated voltage
AC 15.5 kV
Size
195 x 25.4 mm
Utilization category
back-up
Breaking Capacity
45 kA
usable for size/applications
voltage and auxiliary transformers
Standard/Approval
BS
IEC
Shape
cylindrical
Standards/Regulations
BS2692-1
IEC 60282-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
3.15 A
Rated voltage
15.5 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
45 kA
Utilization category
Other
Application
Auxiliary transformer protection
Length
195 mm
Diameter
25.4 mm
Performance category according to IEC 60282-1
Back-up
With striker
No
Standard
IEC
Release characteristic
Other
Installation technique
Air

ETIM for 15.5ABCNA3.15 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 3.15 A
Rated voltage (EF000228) 15.5 kV
Voltage type (EF000187) AC
Utilization category according to IEC 60269 (EF002572) Other
Length (EF001438) 195 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) IEC
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.