EATON - MOELLER 14.3KV 10AMP 3" AIR FUSE 14.3KV 10AMP 3" AIR FUSE 14-3AFINF10 EATON ELECTRIC Fuse-link, LV, 10A, AC 690 V, NH0, gL/gG, IEC, dual indi.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

14.3KV 10AMP 3" AIR FUSE 14-3AFINF10 EATON ELECTRIC Fuse-link, LV, 10A, AC 690 V, NH0, gL/gG, IEC, dual indi..

14.3KV 10AMP 3" AIR FUSE

143AFINF10

14-3AFINF10

EATON - MOELLER

1 Pcs.

Fuse-link, LV, 10A, AC 690 V, NH0, gL/gG, IEC, dual indicator, live gripping lugs 14.3KV 10AMP 3" AIR FUSE Eaton Bussmann series medium voltage BS air fuse, 10 A, 14.3 kV, 200 kA, 76.2 x 565 , Non Indicating Fuse, Air fuse-link, medium voltage, 10 A, AC 14.3 kV, 565 x 76.2 mm, back-up, BS, cylindrical with offset double bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 200 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage BS air fuse
Catalog Number
14-3AFINF10
EAN
5027590190282
Product Length/Depth
565 mm
Product Height
76.2 mm
Product Width
76.2 mm
Product Weight
0.001 g
Compliances
BS 2692-1
Certifications
BS

Electrical data

Amperage Rating
10 A
Voltage rating
14.3 kV
Voltage type
AC
Breaking capacity
200 kA
Performance Cat According To IEC 60282-1
Back-up
Rated frequency - min
50 Hz
Class
Class back-up

Product specification

Fuse indicator
Non Indicating
Construction size
76.2 x 565 mm
Standard
British Standard
Standard
British Standard
Mounting method
Clip-in

ETIM for 14-3AFINF10 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 10 A
Rated voltage (EF000228) 14.3 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 200 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 565 mm
Diameter (EF000551) 76 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.