EATON - MOELLER 12KV 100A 2.5" OIL FUSE 12KV 100A 2.5" OIL FUSE 12OHFMA100 EATON ELECTRIC Oil fuse-link, medium voltage, 100 A, AC 12 kV, BS2692 F01.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

12KV 100A 2.5" OIL FUSE 12OHFMA100 EATON ELECTRIC Oil fuse-link, medium voltage, 100 A, AC 12 kV, BS2692 F01..

12KV 100A 2.5" OIL FUSE

12OHFMA100

12OHFMA100

EATON - MOELLER

3 Pcs.

Oil fuse-link, medium voltage, 100 A, AC 12 kV, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker 12KV 100A 2.5" OIL FUSE Fuse, Oil fuse-link, medium voltage, 100 A, AC 12 kV, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS 2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 40 kA, Optional accessories, Supplied with

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage oil fuse
Catalog Number
12OHFMA100
Model Code
12KV 100A 2.5" OIL FUSE
EAN
5027590432689
UPC
051712534147
Product Length/Depth
254 mm
Product Height
63.5 mm
Product Width
63.5 mm
Product Weight
1900 g
Compliances
BS 2692-1
ESI 12-8
Certifications
IEC Rated
IEC60282-1

Electrical data

Amperage Rating
100 A
Voltage rating
12 kV
Voltage type
AC
Breaking capacity
40 kA
Performance Cat According To IEC 60282-1
Back-up
Class
Class back-up

Product specification

Fuse indicator
with striker
Construction size
63.5 x 254 mm
Standard
British Standard
Standard
British Standard

ETIM for 12OHFMA100 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 100 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 254 mm
Diameter (EF000551) 63.5 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Oil

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.