EATON - MOELLER 12KV 50AMP 2" '6B' AIR FUSE 12KV 50AMP 2" '6B' AIR FUSE 12BDGH6B50 EATON ELECTRIC Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 46.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

12KV 50AMP 2" '6B' AIR FUSE 12BDGH6B50 EATON ELECTRIC Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 46..

12KV 50AMP 2" '6B' AIR FUSE

12BDGH6B50

12BDGH6B50

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 461 mm, back-up, BS, with striker 12KV 50AMP 2" '6B' AIR FUSE Eaton Bussmann series medium voltage BS air fuse, 50 A, 12 kV, 40 kA, 51 x 359 mm, With Striker Fuse, Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 461 mm, back-up, BS, with striker, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage BS air fuse
Catalog Number
12BDGH6B50
EAN
5027590431071
Product Length/Depth
359 mm
Product Height
50.8 mm
Product Width
50.8 mm
Product Weight
2100 g
Compliances
BS 2692-1
Certifications
BS

Electrical data

Amperage Rating
50 A
Voltage rating
12 kV
Voltage type
AC
Breaking capacity
40 kA
Performance Cat According To IEC 60282-1
Back-up
Rated frequency - min
50 Hz
Class
Class back-up

Product specification

Fuse indicator
With Striker
Construction size
51 x 359 mm
Standard
British Standard
Standard
British Standard
Mounting method
Clip-in

ETIM for 12BDGH6B50 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 50 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 359 mm
Diameter (EF000551) 51 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.