EATON - MOELLER 12KV 50AMP 2" '6B' AIR FUSE N/S 12KV 50AMP 2" '6B' AIR FUSE N/S 12BDGN6B50 EATON ELECTRIC Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

12KV 50AMP 2" '6B' AIR FUSE N/S 12BDGN6B50 EATON ELECTRIC Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 ..

12KV 50AMP 2" '6B' AIR FUSE N/S

12BDGN6B50

12BDGN6B50

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 461 mm, back-up, BS 12KV 50AMP 2" '6B' AIR FUSE N/S Eaton Bussmann series medium voltage BS air fuse, 50 A, 12 kV, 40 kA, 51 x 359 mm, Non Indicating Fuse, Air fuse-link, medium voltage, 50 A, AC 12 kV, 51 x 461 mm, back-up, BS, cylindrical, offset bolted tags, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Eaton Moeller 12KV 50AMP 2" '6B' AIR FUSE N/S is an air fuse-link, medium voltage, manufactured for primary side transformer protection across industrial power systems. It interrupts abnormal currents safely without external gas emission.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current (EF000227): 50 A
  • Rated voltage (EF000228): 12 kV
  • Voltage type (EF000187): AC
  • Rated frequency (EF001663): 50 Hz
  • Breaking capacity (EF005617): 40 kA
  • Application (EF000041): Primary side transformer protection
  • Length (EF001438): 510 mm
  • Diameter (EF000551): 51 mm
  • Performance category according to IEC 60282-1 (EF012539): Back-up
  • With striker (EF008175): No
  • Standard (EF009322): British Standard
  • Installation technique (EF001474): Air

More info

▲

General specifications

Product Name
Eaton Bussmann series medium voltage BS air fuse
Catalog Number
12BDGN6B50
EAN
5027590431576
Product Length/Depth
510 mm
Product Height
50.8 mm
Product Width
50.8 mm
Product Weight
2.186 g
Compliances
BS 2692-1
Certifications
BS

Product specifications

Type
Fuse
Application
Amperage Rating
50 A
Fuse indicator
Non Indicating
Fuse size
51 x 359 mm
Breaking capacity
40 kA
Installation technique
Air
Performance Cat According To IEC 60282-1
Back-up
Product application
Primary side transformer protection
Rated frequency - max
50 Hz
Rated frequency - min
50 Hz
Release characteristic
Other
Standard
British Standard
Utilization category
Other
Voltage type
AC
With striker
No
Class
Class back-up
Fuse shape
Cylindrical, offset bolted tags
Fuse diameter
51 mm
Interrupt rating
40 kAIC
Construction size
51 x 359 mm
Mounting method
Clip-in
Voltage rating
12 kV
Fuse type
BDGN

Product Datasheet