12KV 50AMP 2.5" HG OIL FUSE 12OHGMA50 EATON ELECTRIC Oil fuse-link, medium voltage, 50 A, AC 12 kV, BS2692 F..

12KV 50AMP 2.5" HG OIL FUSE

12OHGMA50

12OHGMA50

EATON - MOELLER

3 Pcs.

Oil fuse-link, medium voltage, 50 A, AC 12 kV, BS2692 F02, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker 12KV 50AMP 2.5" HG OIL FUSE Fuse, Oil fuse-link, medium voltage, 50 A, AC 12 kV, BS2692 F02, 359 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage oil fuse
Catalog Number
12OHGMA50
EAN
5027590432795
UPC
051712585545
Product Length/Depth
359 mm
Product Height
63.5 mm
Product Width
63.5 mm
Product Weight
2600 g
Compliances
BS 2692-1
ESI 12-8
Certifications
IEC Rated
IEC60282-1
KEMA

Electrical data

Amperage Rating
50 A
Voltage rating
12 kV
Voltage type
AC
Breaking capacity
40 kA
Performance Cat According To IEC 60282-1
Back-up
Class
Class back-up
Resistance
22.6

Product specification

Fuse indicator
with striker
Construction size
63.5 x 359 mm
Standard
British Standard
Standard
British Standard

ETIM for 12OHGMA50 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 50 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 359 mm
Diameter (EF000551) 63.5 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Oil

Product Datasheet