12KV 25AMP 2" '6B' AIR FUSE Air fuse-link, 25 A, AC 12 kV, 2", 359 x 50.8 mm, back-up, BS, with striker Air fuse-link, medium voltage, 25 A, AC 12 kV, 51 x 461 mm, back-up, BS, with striker, style 6B tags

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Air fuse-link, 25 A, AC 12 kV, 2", 359 x 50.8 mm, back-up, BS, with striker
Fuse, Air fuse-link, medium voltage, 25 A, AC 12 kV, 359 x 50.8 mm, back-up, BS, with striker, cylindrical, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2962-1, Breaking Capacity 40 kA, style 6B tags

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Rated current [I]
25 A
Rated voltage
AC 12 kV
Construction size
2"
Size
359 x 50.8 mm
Utilization category
back-up
Status indicator
with striker
usable for size/applications
Primary side transformer protection
Standard/Approval
BS
Shape
cylindrical
offset bolted tags

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
25 A
Rated voltage
12 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
40 kA
Utilization category
Other
Application
Primary side transformer protection
Length
359 mm
Diameter
51 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

ETIM for 12BDGH6B25 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 25 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 359 mm
Diameter (EF000551) 51 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air