EATON - MOELLER 12KV 10AMP 2" AIR FUSE 12KV 10AMP 2" AIR FUSE 12ADJN1010 EATON ELECTRIC Air fuse-link, medium voltage, 10 A, AC 12 kV, 51 x 254 mm,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

12KV 10AMP 2" AIR FUSE 12ADJN1010 EATON ELECTRIC Air fuse-link, medium voltage, 10 A, AC 12 kV, 51 x 254 mm,..

12KV 10AMP 2" AIR FUSE

12ADJN1010

12ADJN1010

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 10 A, AC 12 kV, 51 x 254 mm, back-up, BS 12KV 10AMP 2" AIR FUSE Eaton Bussmann series medium voltage BS air fuse, 10 A, 12 kV, 12 kA, 51 x 254 mm, Non Indicating Fuse, Air fuse-link, medium voltage, 10 A, AC 12 kV, 51 x 254 mm, back-up, BS, cylindrical, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 12 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Bussmann series medium voltage BS air fuse
Catalog Number
12ADJN1010
EAN
5027590430432
Product Length/Depth
232 mm
Product Height
50.8 mm
Product Width
50.8 mm
Product Weight
1413 g
Compliances
BS 2692-1
Certifications
BS

Electrical data

Amperage Rating
10 A
Voltage rating
12 kV
Voltage type
AC
Breaking capacity
12 kA
Performance Cat According To IEC 60282-1
Back-up
Rated frequency - min
50 Hz
Class
Class back-up

Product specification

Fuse indicator
Non Indicating
Construction size
51 x 254 mm
Standard
British Standard
Standard
British Standard
Mounting method
Clip-in

ETIM for 12ADJN1010 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 10 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 12 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 232 mm
Diameter (EF000551) 51 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) No
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.