EATON - MOELLER 12KV 100AMP 2.5" OIL SEAL FUSE 12KV 100AMP 2.5" OIL SEAL FUSE 12OHGM27100 EATON ELECTRIC Oil fuse-link, medium voltage, 100 A, AC 12 kV, 25.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

12KV 100AMP 2.5" OIL SEAL FUSE 12OHGM27100 EATON ELECTRIC Oil fuse-link, medium voltage, 100 A, AC 12 kV, 25..

12KV 100AMP 2.5" OIL SEAL FUSE

12OHGM27100

EATON - MOELLER

3 Pcs.

Oil fuse-link, medium voltage, 100 A, AC 12 kV, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker Oil Fuse Cartridge, MT, 100 A, AC 12 kV, 254 x 63.5 mm, Back-Up, BS, IEC, ESI, with Striker Fuse, Oil fuse-link, medium voltage, 100 A, AC 12 kV, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 40 kA

Automation > Medium-/high voltage fuse
Bussmann fuses

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Oil fuse-link, medium voltage, 100 A, AC 12 kV, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker
Fuse, Oil fuse-link, medium voltage, 100 A, AC 12 kV, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 40 kA

Delivery program

Product range
Fuse
Basic function
Oil fuse-link
Field of application
medium voltage
Rated current [I]
100 A
Rated voltage
AC 12 kV
Size
254 x 63.5 mm
Utilization category
back-up
Status indicator
with striker
Description
oil-tight
Breaking Capacity
40 kA
usable for size/applications
protection of primary side transformer, and oil-filled fuse switch combination unit
Standard/Approval
BS
IEC
ESI
Shape
cylindrical
Standards/Regulations
BS2692-1
IEC 60282-1
ESI 12-8

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
100 A
Rated voltage
12 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
40 kA
Utilization category
Other
Application
Primary side transformer protection
Length
254 mm
Diameter
63.5 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Oil

ETIM for 12OHGM27100 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 100 A
Rated voltage (EF000228) 12 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 40 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 395 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Oil

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.