EATON - MOELLER DIII-SO/63/3-R-PS DIII-SO/63/3-R-PS 110395 Y7-110395 EATON ELECTRIC Bus-mounted fuse base, 63A, 690 V, DIII/E33, 54mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DIII-SO/63/3-R-PS 110395 Y7-110395 EATON ELECTRIC Bus-mounted fuse base, 63A, 690 V, DIII/E33, 54mm

DIII-SO/63/3-R-PS

110395

Y7-110395

EATON - MOELLER

1 Pcs.

Bus-mounted fuse base, 63A, 690 V, DIII/E33, 54mm DIII-SO/63/3-R-PS Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure. Bus-mounted fuse base, 63A, 690 V, DIII/E33, 54mm, PS

Automation > D-system fuse base
Industrial Fuse Bases

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton xEffect SASY 60i busbar system device DIII
Catalog Number
110395
Model Code
DIII-SO/63/3-R-PS
EAN
4015081099337
Product Length/Depth
295 mm
Product Height
160 mm
Product Width
267 mm
Product Weight
0.279 kg
Compliances
RoHS conform
Certifications
VDE 0636 Part 301
IEC/EN 60269-1

Delivery program

Type
Model
Fitted screw
Amperage Rating
63 A
Number of Poles
Three-pole

Technical data - electrical

Voltage rating
690 V
Voltage rating at AC
  • 690 V AC
  • Contacts: 690 V AC
Rated operational voltage (Ue) - max
690 V
Rated impulse withstand voltage (Uimp)
4 kV
Rated operation current (Ie)
63 A
Rated conditional short-circuit current tested with links
50 kA
Conventional thermal current ith of auxiliary contacts (1-pole, open)
63 A
Current heat loss per contact at Ie
3.34 W
Frequency rating
40 Hz - 60 Hz
Frequency rating of contacts
40 Hz - 60 Hz
Overvoltage category
III
Pollution degree
3

Technical data - mechanical

Enclosure width
200 mm
Frame
E33, D III
Mounting method
Rail system
Mounting position
Vertical or horizontal
Mounting width
54 mm
Material
Plastic
Degree of protection
IP20 enclosed
Distance between busbar centers
60 mm
Terminals
Lift terminals
Terminal capacity (solid wire)
1.5 mm² - 25 mm² at box terminal
1.5 mm² - 25 mm²
Construction size
DIII
Thread type
E33
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Design verification as per IEC/EN 61439 - technical data

Heat dissipation per contact with fuse link at Ie
10 W
Permitted heat loss from fuse links - max
7 W
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Additional information

Functions
Basic device
D busbar mounted fuse device
Uninterrupted operation (Control mode)
Special features
  • 35 °C normal temperature
  • At 55 °C with reduced operating current
  • Including protective shroud with front and bottom plate
  • Delivery, empty, without screw cap, with marking plate
Used with
12 mm x 5/10 mm rail
30 mm x 5/10 mm rail
20 mm x 5/10 mm rail
25 mm x 5/10 mm rail
Double T profile
Busbar fuse material
185 mm system
60 mm system
Gauge screw

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.