Images are for illustrative purposes only. Please refer to data sheet for details
04DILE-C 230258 Y7-230258 EATON ELECTRIC Auxiliary contact, 4 N/C, surface mounting, spring clamp connection
04DILE-C
230258
Y7-230258
EATON - MOELLER
1 Pcs.
Auxiliary contact, 4 N/C, surface mounting, spring clamp connection
04DILE-C
Eaton Moeller® series DILE Auxiliary contact module, 4 pole, 4 NC, Front fixing, Spring-loaded terminals, DILE(E)M…-C, DILER…-C
Auxiliary contact module, with interlocked opposing contacts, Switching elements according to EN 50005, Switching elements according to EN 50012 are to be preferred., Version E combinations correspond to EN 50011 and are to be preferred., Function: for standard applications, 4 pole, Connection technique: Spring-loaded terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, Rated operational current AC-15 380 V 400 V 415 V: Ie= 2 A, Rated operational current AC-15 380 V 400 V 500 V: Ie= 1.5 A, Contacts N/C = Normally closed: 4 NC, Mounting type: Front fixing, For use with: DILE(E)M-10-C(-G)(…), DILE(E)M-01-C(-G)(…) , DILER40(-G)-C, DILER31(-G)-C, DILER22-C, Instructions: Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILE(E)M, Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open), Code number and version of combination Distinctive number: 44 E, 35, 26
Automation > Auxiliary contact block Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Eaton Moeller® series DILE Accessory Auxiliary contact module
Catalog Number
230258
Model Code
04DILE-C
EAN
4015082302580
Product Length/Depth
39 mm
Product Height
37 mm
Product Width
45 mm
Product Weight
0.042 kg
Certifications
IEC/EN 60947 UL File No.: E29184 VDE 0660 CSA CSA-C22.2 No. 14-05 UL 508 IEC/EN 60947-4-1 UL CE CSA Class No.: 3211-03 CSA File No.: 012528 UL Category Control No.: NKCR
Features & Functions
Electric connection type
Spring clamp connection
Features
Interlocked opposing contacts within an auxiliary contact module (according to IEC 60947-5-1 Annex L)
Fitted with:
Switching elements according to EN 50005 Interlocked opposing contacts
Functions
For standard applications
Number of poles
Four-pole
General
Lifespan, mechanical
150,000 Operations (at 240 V, DC, L/R = 50 ms: 2 contacts in series 0.5 A) 200,000 Operations (at 240 V, AC-15) 10,000,000 Operations (AC operated) 20,000,000 Operations (DC operated)
Model
Top mounting
Mounting method
Front fastening
Mounting position
As required (except vertical with terminals A1/A2 at the bottom)
Operating frequency
9000 Operations/h
Overvoltage category
III
Pollution degree
3
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
6000 V AC
Shock resistance
10 g, N/O contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 8 g, N/C contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
Terminal capacity (flexible with ferrule)
1 x (1 - 2.5) mm² 2 x (1 - 2.5) mm²
Terminal capacity (solid)
2 x (1 - 2.5) mm² 1 x (1 - 2.5) mm²
Terminal capacity (solid/stranded AWG)
Single 16 – 14, double 16 – 14
Screwdriver size
0.6 x 3.5 mm, Spring-loaded terminals
Electrical rating
Rated operational voltage (Ue) at AC - max
600 V
Rated insulation voltage (Ui)
690 V
Rated operational current (Ie)
2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series) 1.5 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series) 2.5 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 0.5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
4 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
2 A
Rated operational current (Ie) at AC-15, 500 V
1.5 A
Safe isolation
300 V AC, Between coil and auxiliary contacts, According to EN 61140 300 V AC, Between auxiliary contacts, According to EN 61140
Short-circuit rating
Short-circuit protection rating
10 A fast, 500V, Maximum fuse, Short-circuit rating without welding, Contacts
Short-circuit protection rating without welding
6 A gG/gL, 500 V, Max. Fuse, Contacts
Conventional thermal current Ith
Conventional thermal current ith of auxiliary contacts (1-pole, open)
10 A
Switching capacity
Switching capacity (auxiliary contacts, general use)
0.5 A, 250 V DC, (UL/CSA) 10 A, 600 V AC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
P300, DC operated (UL/CSA) A600, AC operated (UL/CSA)
Contacts
Code number
26 in combination with DILER-22 35 in combination with DILER-31(-G) 44E