View larger
131B9350 FC-102P55KT4E55H1XGC1XXSXXXXAXBXCXXXXDX DANFOSS DRIVES FC-102P55KT4E55H1XGC1XXSXXXXAXBXCXXXXDX
1212519
1212519
DANFOSS DRIVES
1 unit
Automation > VLT FC102 HVAC
VLT FC102 HVAC - DANFOSS DRIVES
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Industrial motor applications rely on frequency converters like the Danfoss Drives unit (131B9350 FC-102P55KT4E55H1XGC1XXSXXXXAXBXCXXXXDX) to dynamically adjust motor speeds, reduce mechanical stress, and improve overall system efficiency.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product View (Switch): GLBL
- Product Group: FC-
- Series: 102
- Power Rating: P55K
- Phase: T
- Mains Voltage: 4
- Enclosure: E55
- RFI Filter: H1
- Brake - Safe Stop: X
- LCP: G
- Coating PCB: C
- Mains Option: 1
- Adaptation A: X
- Adaptation B: X
- Software Release: SXXX
- Software Language Pack: X
More info
▲Frequency Converter
FC-102P55KT4E55H1XGC1XXSXXXXAXBXCXXXXDX
VLT® HVAC Drive FC-102
(P55K) 55 KW / 75 HP,
Three phase, 380 - 480 VAC, IP55 / Type 12
(H1) RFI Class A1/B (C1)
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB, Mains Disconnect
Latest release std. SW.
Frame: C1
No A Option, No B Option
No C1 option, No D option
Other options according to Model Code
Product details
| Gross weight | 44.81 Kilogram | ||
| Net weight | 41.81 Kilogram | ||
| Volume | 176.054 Liter | ||
| EAN | 5702427383647 |
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® HVAC Drive FC- | |
| Series | 102 | 102 | |
| Power Rating | P55K | (P55K) 55 KW / 75 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 4 | 380 - 480 VAC | |
| Enclosure | E55 | IP55 / Type 12 | |
| RFI Filter | H1 | (H1) RFI Class A1/B (C1) | |
| Brake - Safe Stop | X | No brake chopper | |
| LCP | G | Graphical Loc. Cont. Panel | |
| Coating PCB | C | Coated PCB | |
| Mains Option | 1 | Mains Disconnect | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | AX | No A Option | |
| B Option | BX | No B Option | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | DX | No D option | |
| Frame Size | C1 | C1 | |
| Product Catalog | GLBL | Global (Standard) | |
| Typecode Part 1 | FC-102P55KT4E55H1XGC | ||
| Typecode Part 2 | 1XXSXXXXAXBXCXXXXDX | ||
| Power 110% (NO) [KW] | 55 | 55 | |
| Height [mm] | 685,0 | 685,0 | |
| Width w/ no C options [mm] | 308,0 | 308,0 | |
| Depth [mm] | 311,0 | 311,0 | |
| Depth with Option A/B [mm] | 311,0 | 311,0 | |
| kVA | 73.4 | 73.4 | |
| Power Loss NO [W] | 1083 | 1083 | |
| Power Loss NO [W] | 1083 | 1083 | |
| Continuous Current (NO) [A] | 106 | 106 | |
| Intermittent Current (NO) [A] | 117 | 117 | |
| Continuous Current (NO) [A] | 105 | 105 | |
| Intermittent Current (NO) [A] | 116 | 116 | |
| Calculated Gross Weight [kg] | 44.81 | ||
| Calculated Net Weight [kg] | 41.81 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Plant from Orderline | B901 | B901 | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Producing plant | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-102P55KT4E55H1XGC | ||
| Modelcode02 | 1XXSXXXXAXBXCXXXXDX | ||
| Delivering plant | ERR01 | ERR01 |