CARLO GAVAZZI CLD4MA2D230 CLD4MA2D230 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING 2-DIN SENSING FUNCTION Filling and Empty.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CLD4MA2D230 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING 2-DIN SENSING FUNCTION Filling and Empty..

CLD4MA2D230

10000

CARLO GAVAZZI

1 Pcs.

Selected parameters SYSTEM System HOUSING 2-DIN SENSING FUNCTION Filling and Emptying CONNECTION Terminals OUTPUT Relay DPDT MATERIAL Plastic Others HOUSING 35,5 x 81 x 60 mm SENSING FUNCTION 250 oHm to 500 koHm MATERIAL NORYL ADDITIONAL Alarm HiHi and LoLo 2 to 4 point conductive level controller with potentiometer, Power supply 230 VAC Conductive 2 to 4-point level controller, DIN rail mount, filing-emptying with multifunctions, sensitivity 250 ohm -500 Kohm, SPST + SPDT relay output, supply voltage 230VAC, 35.5x81x60,2mm housing, IP20

Automation > (Fill) level monitoring relay
Conductive Level

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

CLD4MA2D230 Carlo Gavazzi conductive liquid level relay is engineered to monitor and control fluid levels in tanks, wells, and industrial processing vessels by detecting electrical conductivity between immersed electrodes. Such devices prevent dry-running conditions or overflow hazards in fluid management systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Screw connection
  • With detachable clamps (EF003340): No
  • Number of inputs for electrodes (EF003427): 5
  • Min. adjustable operate delay time (EF008195): 1 s
  • Max. permitted operate delay time (EF008194): 1 s
  • Min. adjustable off-delay time (EF008192): 1 s
  • Max. permitted off-delay time (EF008191): 1 s
  • Response value sensitivity adjustable (EF003429): No
  • Number of contacts as normally closed contact (EF008255): 0
  • Number of contacts as normally open contact (EF008256): 1
  • Number of contacts as change-over contact (EF008257): 1
  • Physical measurement principle (EF008238): Conductive
  • Cascadable (EF000507): No
  • Width (EF000008): 35.5 mm
  • Height (EF000040): 81 mm
  • Depth (EF000049): 60.2 mm

More info

▲

Specifications

Number of input probes
5
Adjustable sensitivity
No
Number of relay outputs
1
Min on-delay time
1 s
Max on-delay time
1 s
Min off-delay time
1 s
Max off-delay time
1 s
Rated operating voltage
0 V ... 0 V
Connection type
Screw terminals
Product width
35.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.