CARLO GAVAZZI DPC01DM69 DPC01DM69 CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABL.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DPC01DM69 CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABL..

DPC01DM69

10000

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 45 mm POWER SUPPLY RANGE 600÷690 VAC MONITORING FUNCTION Under and over voltage, phase sequence/loss, asymmetry, tolerance MOUTING DIN-rail INPUT RANGE 600÷690 VAC OTHERS VLN monitoring Three-phase control relay of max. and min. voltage, sequence, loss and phase asymmetry 3-phase monitoring relay for phase loss, sequence, asymmetry, tolerance, over and undervoltage, nominal range 600-690 V AC, delay on alarm 0.1-30 s, 2 SPDT relay outputs, 45 mm DIN-rail housing

Automation > Phase monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The DPC01DM69 Carlo Gavazzi monitoring relay is an advanced protective device utilized in industrial power distribution to continuously evaluate three-phase line parameters. These units protect costly electrical assets by detecting voltage drops, surges, and phase failures before damage occurs. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Screw connection
  • With detachable clamps (EF003340): No
  • Phase sequence monitoring (EF003412): Yes
  • Phase failure detection (EF003413): Yes
  • Function under voltage detection (EF003414): Yes
  • Function over voltage detection (EF003415): Yes
  • Phase imbalance monitoring (EF003416): Yes
  • Min. adjustable delay-on energization time (EF008190): 0.1 s
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Width (EF000008): 45 mm
  • Height (EF000040): 80 mm
  • Depth (EF000049): 99.5 mm

More info

▲

Specifications

Mounting
Industrial DIN-rail
Function
Phase loss; Phase sequence; Overvoltage; Undervoltage; Voltage asymmetry
3-phase voltage range
600-690 Vac
Frequency range
50-60 Hz
Output
2 relays
Time delay
Delay on alarm
Approvals, marks, declaration
for Europe; for North America; for China; for Australia
Setting method through NFC
No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.