CARLO GAVAZZI PWB01CM4810A PWB01CM4810A CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIA.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PWB01CM4810A CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIA..

PWB01CM4810A

10000

CARLO GAVAZZI

1 Pcs.

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE Power and power factor monitoring Others SIZE 36 mm POWER SUPPLY RANGE 380÷415 VAC MONITORING FUNCTION PF monitoring MOUTING Plug-in INPUT RANGE 0.1-0.99 DELAY 1, adjustable Three-phase load control relay in balanced three-phase system (TRMS), Undecal base mount 3-phase power factor monitoring relay, measuring range up to 5A, 10A or with MI current transformers, 1 SPDT relay output, 36 mm plug-in housing

Automation > Effective power (cos phi) monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A PWB01CM4810A Carlo Gavazzi monitoring relay offers plug-in convenience while maintaining rigorous supervision over three-phase power networks to prevent electrical fault conditions. These devices are standard additions to modern control panels seeking to protect sensitive machinery from fluctuating line voltages.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Plug-in connection
  • With detachable clamps (EF003340): No
  • Rated operating frequency (EF007024): 45 Hz
  • Number of phases (EF000351): 3
  • Min. adjustable delay-on energization time (EF008190): 0.1 s
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Number of contacts as change-over contact (EF008257): 1
  • Width (EF000008): 36 mm
  • Height (EF000040): 80 mm
  • Depth (EF000049): 94 mm

More info

▲

Specifications

Mains voltage
380-480 V AC
Mounting
Plug-in
Power function
Power factor
3-phase voltage range
380-480 Vac
Time delay
Delay on alarm
Output
1 x SPDT change-over contact
Max. permitted delay-on energization time
30 s
Type of electric connection
Plug-in connection
With approval according to UL
Yes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.