Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 22,5 mm POWER SUPPLY RANGE 380÷480 VAC MONITORING FUNCTION Asymmetry, phase sequence/loss MOUTING DIN-rail INPUT RANGE 380÷480 VAC DELAY 1, adjustable OTHERS VLN monitoring Three-phase sequence control, loss and phase asymmetry relay, DIN Rail Mount 3-phase monitoring relay for phase loss, sequence, asymmetry, nominal range 380-480 V AC, delay on alarm 0.1-30 s, SPDT relay output, regenerated voltage detection, 22.5 mm DIN-rail housing

Automation > Phase monitoring relay
Monitoring Relays and Measurement Current Transformers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered for electrical system protection, the DPB02CM48 CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE.. continuously checks phase availability and sequence in multi-phase supplies to prevent hardware damage. Such monitoring devices are widely used in industrial control panels to disconnect power safely when supply anomalies arise.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Screw connection
  • With detachable clamps (EF003340): No
  • Phase sequence monitoring (EF003412): Yes
  • Phase failure detection (EF003413): Yes
  • Function under voltage detection (EF003414): No
  • Function over voltage detection (EF003415): No
  • Phase imbalance monitoring (EF003416): Yes
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Width (EF000008): 22.5 mm
  • Height (EF000040): 83.5 mm
  • Depth (EF000049): 99.5 mm

More info

▲

Specifications

Mounting
Industrial DIN-rail
Function
Phase loss; Phase sequence; Voltage asymmetry
3-phase voltage range
380-480 Vac; 440-480 Vac
Frequency range
50-60 Hz
Output
1 relay
Time delay
Delay on alarm
Approvals, marks, declaration
for Europe; for North America; for China; for Australia
Setting method through NFC
No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.